CSFSAM00 ----------------- ICSF - Key Administration ---------------
OPTION ===> 2
Enter the number of the desired option.
1 Create - Create key generator control statements
2 Data Set - Specify data sets for processing
3 Submit - Invoke Key Generator Utility Program (KGUP)
4 Refresh - Activate an existing cryptographic key data set
Press ENTER to go to the selected option
Press END to exit to the previous panel
The Specify KGUP Data Sets panel appears. See Figure 2.
CSFSAE20 ---------------- ICSF - Specify KGUP Data Sets ------------
COMMAND ===> _
Enter data set names for all cryptographic files.
Cryptographic Key (DDNAME = CSFCKDS)
Data Set Name ===> ____________________________________________
Control Statement Input (DDNAME = CSFIN)
Data Set Name ===> ____________________________________________
Volume Serial ===> ______ (if uncataloged)
Diagnostics (DDNAME = CSFDIAG) (use * for printer)
Data Set Name ===> ____________________________________________
Volume Serial ===> ______ (if uncataloged)
Key Output (DDNAME = CSFKEYS)
Data Set Name ===> ____________________________________________
Volume Serial ===> ______ (if uncataloged)
Control Statement Output (DDNAME = CSFSTMNT)
Data Set Name ===> ____________________________________________
Volume Serial ===> ______ (if uncataloged)
Press ENTER to set the data set names. Press END to exit to the previous panel.
This panel contains all the data sets that KGUP uses for input or output during processing. In the Data Set Name field under each type of data set, you specify the name of the data set for KGUP to use.
You must initialize the CKDS by using the method that is described in Initializing the CKDS and PKDS at First-Time Startup. The data set can be any disk copy of a CKDS that is enciphered under the current master key.
If you specified a control statement input data set on the KGUP Control Statement Data Set Specification panel, the data set name appears in the Control Statement Input Data Set Name field on this panel. If you change the data set name on this panel, it automatically changes on the KGUP Control Statement Data Set Specification panel. Refer to Figure 2 for an example of the KGUP Control Statement Data Set Specification panel.
You do not have to allocate this data set when you specify the data set in this field. If the data set does not already exist, then a job control language statement that allocates the data set can be used when you submit the job.
If you enter an * in the Diagnostics Data Set Name field, the information is printed directly to a printer instead of a data set.
You do not have to allocate this data set when you specify the data set in this field. If the data set does not already exist, then a job control language statement that allocates the data set can be used when you submit the job.
You do not have to allocate this data set when you specify the data set in this field. If the data set does not already exist, then a job control language statement that allocates the data set can be used when you submit the job.
For a more complete description of each of the data sets, see Specifying KGUP data sets.
The data sets that you name appear on this panel the next time you access it.
An example of a Specify KGUP Data Sets panel with the names of data sets specified for KGUP processing is shown in Figure 3.
CSFSAE20 ---------------- ICSF - Specify KGUP Data Sets ------------
COMMAND ===> _
Enter data set names for all cryptographic files.
Cryptographic Key (DDNAME = CSFCKDS)
Data Set Name ===> TEST.CSFCKDS________________________________
Control Statement Input (DDNAME = CSFIN)
Data Set Name ===> CSFIN.TESTDS1P(TEST)________________________
Volume Serial ===> ______ (if uncataloged)
Diagnostics (DDNAME = CSFDIAG) (use * for printer)
Data Set Name ===> *___________________________________________
Volume Serial ===> ______ (if uncataloged)
Key Output (DDNAME = CSFKEYS)
Data Set Name ===> TEST.CSFKEYS________________________________
Volume Serial ===> ______ (if uncataloged)
Control Statement Output (DDNAME = CSFSTMNT)
Data Set Name ===> TEST.CSFSTMNT_______________________________
Volume Serial ===> ______ (if uncataloged)
Press ENTER to set the data set names. Press END to exit to the previous panel.