Steps for adding a CCA coprocessor after first time Pass Phrase Initialization

Use this section when you add more coprocessors to your system. ICSF will load the same master key values into the new coprocessors.

You must use the same pass phrase as when you originally ran PPINIT to initialize the active CKDS and PKDS.
Note: At least one coprocessor must be active and the PKA callable services control must be enabled where applicable.
  1. Type the pass phrase in the space that is provided and select the 'Add coprocessors' option by placing an "s" in the "_" field.
  2. Press ENTER to run the utility.

    The utility will calculate the master key values and load the master keys on all coprocessors that are not active.

    Messages on the bottom half of the panel display the progress of the utility.

  3. When the utility has completed successfully, press END to return to the primary menu.