Defining diagnostic snapshot log streams
For optimal performance of the Incident Log task, it is recommended that your installation define operations log (OPERLOG) and logrec log streams for the CEA component of z/OS®. Doing so allows the system logger component to determine the storage characteristics for storing diagnostic snapshots.
How to check if this step is done
To display the OPERLOG logstream, enter the following command:
D LOGGER,L,LSN=SYSPLEX.OPERLOG
Figure 1 shows
the expected results:
Figure 1. Expected results from the D
LOGGER command
IXG601I 15.26.03 LOGGER DISPLAY 070
INVENTORY INFORMATION BY LOGSTREAM
LOGSTREAM STRUCTURE #CONN STATUS
--------- --------- ------ ------
SYSPLEX.OPERLOG LOGGER_STR1 000004 IN USE
SYSNAME: P00
DUPLEXING: LOCAL BUFFERS
SYSNAME: P01
DUPLEXING: LOCAL BUFFERS
SYSNAME: P02
DUPLEXING: LOCAL BUFFERS
SYSNAME: P03
DUPLEXING: LOCAL BUFFERS
GROUP: PRODUCTION
NUMBER OF LOGSTREAMS: 000001
If this step is not already done
To create the log streams, you can use a batch job like sample job CEASNPLG, which is supplied by IBM® in SYS1.SAMPLIB(CEASNPLG). The CEASNPLG job deletes and redefines CEA diagnostic snapshot model log streams, using the IBM utility program, IXCMIAPU. For information about the IXCMIAPU utility, see z/OS MVS Setting Up a Sysplex.