IEF004I jobname procstep stepname ddname +
xxxx ERROR PROCESSING UNIT AFFINITY REQUEST ExplanationThe system detected an error while processing a VOLUME=REF reference to a DD statement with a UNIT=AFF reference. In the message text:
System actionThe system ends the job. System programmer responseLook at the messages in the job log. If the JOB statement did not specify MSGLEVEL=(1,1), specify it and run the job again. If the problem persists, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the SYSOUT output for the job. Programmer responseCheck that the step name on the refer back is unique. Check the spelling of the names on the refer back and the unit affinity request on the referenced statement. After correcting the error, submit the job again. SourceAllocation ModuleThe detecting module is IEFAB42B. |