z/OS MVS System Messages, Vol 8 (IEF-IGD)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


IEF474I

z/OS MVS System Messages, Vol 8 (IEF-IGD)
SA38-0675-02

IEF474I
jobname [procstep] stepname ddname[+ xxx] - UNIT OR VOLUME IN USE BY SYSTEM FUNCTION - CANNOT BE ALLOCATED

Explanation

The system could not allocate the volume or unit requested because it was in use by a system function, such as OLTEP or a system utility.

In the message text:
jobname
The name of the job.
procstep
The name of the step in the procedure.
stepname
The name of the job step.
ddname
The name of the DD statement.
+ xxx
The relative position of a data set within a concatenation of data sets, including all data sets implicitly concatenated (through GDG ALL or OPTCD=B requests). See z/OS MVS JCL User's Guide for more information on GDG ALL or OPTCD=B requests when used within a set of concatenated data sets. The first data set of a concatenation would be +000, but the value +000 is never shown.

System action

The system ends the job.

Programmer response

Resubmit the job when the system function has completed.

Source

Allocation

Module

IEFAB425, IEFAB433, IEFAB441, IEFAB479, IEFAB482

Routing code

11

Descriptor code

-

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014