Previous topic |
Next topic |
Contents |
Contact z/OS |
Library |
PDF
IEF008I z/OS MVS System Messages, Vol 8 (IEF-IGD) SA38-0675-02 |
|
IEF008I DASD DEVICE devnum NOT VARIED ONLINE -
VOLUME SERIAL NOT VALID ExplanationThe system detected a volume serial number that was not valid for a direct access storage device (DASD) during allocation processing of one of the following:
In the message text:
System actionThe system does one of the following:
Operator responseNotify the system programmer of the problem. If the problem occurred because of:
System programmer responseEnsure that the device is functioning correctly. Verify that the device has a correct standard label. If necessary, refresh the volume label and try to vary the device online so that the system can attempt to verify the volume serial. Further errors can indicate that the device experienced a hardware failure; in this case, contact hardware support. SourceAllocation ModuleIEFAB4F8 Routing code* Descriptor code/ |
Copyright IBM Corporation 1990, 2014
|