System Management Facilities (SMF) found that the SYS1.MANn recording data set is too small to hold the largest possible SMF record (32 kilobytes) and the control information that is required to segment the record.
SMF initialization or SET SMF command processing continues but ignores the SYS1.MANn data set. If at least one valid SMF recording data set is available, SMF continues recording and issues message IEE360I. Otherwise, SMF does no recording.
Notify the system programmer.
Recreate the SYS1.MANn data set using the access method services DEFINE utility and specifying a larger size. Use the access method services LISTCAT utility to check the size of all SMF recording data sets. A data set is large enough if the LISTCAT output shows a HI-ALLOC-RBA value of at least 36863 for the data set. Recreate any data set that is too small.
System Management Facilities (SMF)
IEEMB822
2,10
5