IEE951I
DSORG OF SYS1.MANn DATA SET IS NOT VSAM. DATA SET CANNOT BE USED.

Explanation

System Management Facilities (SMF) found that the SYS1.MANn recording data set specified in the DSNAME parameter in the SMFPRMxx parmlib member or in the reply to message IEE357A is not a VSAM data set. All SMF recording data sets must be VSAM data sets.

In the message text:
SYS1.MANn
The data set, with a suffix of n.

System action

SMF initialization or SET SMF command processing continues. If at lease one valid SMF recording data set is available, SMF continues recording and issues message IEE360I. Otherwise, SMF does no recording.

Operator response

Notify the system programmer.

System programmer response

Respond with one of the following:
  • Recreate the SYS1.MANn data set.
  • Modify the DSNAME parameter in the SMFPRMxx parmlib member to include only VSAM data sets.

Source

System Management Facilities (SMF)

Module

IEEMB822

Routing code

2,10

Descriptor code

5