IEE726D
ENTER ADDITIONAL SLIP PARAMETERS, [,‘END’,] OR ‘CANCEL’

Explanation

A SLIP SET command was specified without an END parameter. Message IEE725I, which lists the SLIP parameters, preceded this message. Reply to this message to do one of the following:
  • Add new SLIP parameters
  • Change existing SLIP parameters
  • Accept the parameters already specified
  • Cancel the SLIP command
In the message text:
‘END’
A SLIP command, other than SLIP MOD or SLIP DEL, was entered.

System action

The system waits for the operator to reply.

Operator response

Do one of the following:
  • Reply REPLY id,prm,prm,...,[END] to add parameters or to change the parameters indicated in message IEE725I.

    To complete the SLIP SET command, specify END as the last parameter. If END is not specified, the system will issue message IEE725I again to display the updated list of parameters.

    The reply can add or change any parameter in any order, except the following positional parameters. These parameters must be added immediately after the SET parameter:
    • IF
    • SA
    • SB

    New parameters replace original parameters in their entirety.

    If an incomplete SLIP parameter was specified (for example, if the closing parenthesis was omitted on the last parameter), continue the parameter and complete it in the beginning of the reply.

  • Reply REPLY id,CANCEL to cancel the original SLIP command.
  • Reply REPLY id,END to accept the parameters in message IEE725I.

id is the identifier preceding the message number.

Source

SLIP

Module

IEECB909

Routing code

*

Descriptor code

5