IEE194I
CF SCM REQUEST NOT FULLY SATISFIED – reason

Explanation

The system was not able to configure the full amount of storage-class memory (SCM) that was requested with the CONFIG SCM command.

In the message text, reason can be one of the following:
INSUFFICIENT OFFLINE SCM
Less than the requested amount of SCM is eligible to be brought online.
INSUFFICIENT ONLINE SCM
Less than the requested amount of SCM is eligible to be brought offline.
TIMEOUT OCCURRED
The system attempted to physically configure the SCM online, but could not determine that the reconfiguration was performed.
INTERNAL ERROR, DIAG1=xxxxxxxx
An internal error occurred or an abnormal condition was detected while processing the CONFIG command. The DIAG1 value is internal diagnostic information to supply to IBM when requesting service.

System action

The system configures a portion of the requested amount of SCM and continues processing.

Operator response

Notify the system programmer.

System programmer response

Examine the amount of SCM that was requested to be brought online and verify that the amount is correct.

If the command was rejected because of a timeout condition, retry the command. If the command continues to be rejected with the timeout condition, contact IBM service.

If the message was issued with the INTERNAL ERROR reason text, contact IBM service and provide the internal diagnostic information value.

Source

Reconfiguration

Module

IEEVSCM

Routing code

Note 2

Descriptor code

5