IEE174I (form 12 of 36)
hh.mm.ss DISPLAY M [idr] CHPID STATUS OUT OF SYNC, PHYSICAL=status, LOGICAL=status

Explanation

CHPID STATUS OUT OF SYNC
A physical versus logical mismatch in the channel path status has been detected. One of the reasons this may occur is if the Hardware Management Console (HMC) is used to configure this channel path on or off. This causes the operating system's (S/W) view to be out of sync with the actual state (H/W) and creates a physical versus logical mismatch.
PHYSICAL
Channel path's status as reported by hardware.
LOGICAL
Software's representation of the channel path's physical status.
STATUS
Status of the channel path, which is one of the following:
  • ONLINE
  • OFFLINE

Operator response

If the use of HMC caused this mismatch, bring the channel path status back in sync by using one of the following MVS™ operator commands:
  • If the physical status is online, CONFIG CHP (chp), ONLINE
  • If the physical status is offline, CONFIG CHP (chp), OFFLINE

Module

IEEDMCHP

Routing code

-

Descriptor code

4