Explanation
A CONTROL or DISPLAY command specified an L=name-a parameter
incorrectly.
In the message text:
- L={name|name,a}
- The parameter.
- text
- One of the following lines:
- name-a NOT AN AREA
- The area specified by the name-a parameter:
- Was not valid
- Does not exist
- Was other than Z for a non-cathode ray tube (CRT) console
- Was Z for a status display console.
- name NOT A CONSOLE
- The console named name does not exist or is
not active.
- name FULL CAPABILITY
- The console named name is not one of the following:
- The requester's own console
- A message stream (MS) console
- A status display (SD) console
The console must have master authority or RACF® approval
to route something to an FC console.
- ON THIS COMMAND
- The name parameter was specified, but should not have been, on
one of the following commands:
CONTROL S CONTROL D
CONTROL E,N CONTROL D,N
CONTROL E CONTROL D,N,HOLD
CONTROL E,SEG CONTROL D,PFK
CONTROL E,PFK CONTROL N,PFK
CONTROL C,E
CONTROL C,I
CONTROL C,A
- name OUTPUT ONLY
- One of the following occurred:
- An attempt was made to make a console full capability using the
CONTROL V,USE = FC command. The console was an output only device.
- An attempt was made to define areas using the CONTROL A,nn command
on a console that is in message stream mode.
- name SUBSYSTEM CONSOLE
- An attempt was made to route messages to a console under the control
of another subsystem.
- name STATUS DISPLAY
- An attempt was made to reroute messages to a status display console
named name using the L=name-a parameter.
- name SYSTEM CONSOLE
- An attempt was made to issue a CONTROL S command on the system
console.
- name NOT IN PD MODE
- An attempt was made to issue a CONTROL S command on the system
console that was not in Problem Determination (PD) mode.
- COMMAND ISSUED IS command
- command is the text of the command that was
originally entered.
System action
The system rejects the command.
Operator response
Depending on the message
text,
do the following:
- name NOT AN AREA
- Change the area specification. Enter the command again.
- name NOT A CONSOLE
- Change the console name and reenter the command.
- name FULL CAPABILITY
- Reenter the command by omitting the L=name-a parameter
to have the response come to your own console, if desired.
- ON THIS COMMAND
- Enter the command again without the name parameter.
- name OUTPUT ONLY
- The console may be altered to status display mode by using the
CONTROL V,USE=SD command. Then enter the CONTROL A,nn command
again.
- name SUBSYSTEM CONSOLE
- name STATUS DISPLAY
- Change the console name specification. Enter the command again.
- name SYSTEM CONSOLE
- Change the console name specification and enter the command again.
- name NOT IN PD MODE
- Change the system console to get into Problem Determination (PD)
mode and enter the command again.
Source
Module
IEE6703D, IEE6803D, IEE6903D, IEE7503D, IEE7703D,
IEE8A03D, IEE8B03D, IEE2003D
Routing code
Descriptor code