IEE926I
L={name|name,a} OPERAND INVALID-text [COMMAND ISSUED IS command]

Explanation

A CONTROL or DISPLAY command specified an L=name-a parameter incorrectly.

In the message text:

L={name|name,a}
The parameter.
text
One of the following lines:
name-a NOT AN AREA
The area specified by the name-a parameter:
  • Was not valid
  • Does not exist
  • Was other than Z for a non-cathode ray tube (CRT) console
  • Was Z for a status display console.
name NOT A CONSOLE
The console named name does not exist or is not active.
name FULL CAPABILITY
The console named name is not one of the following:
  • The requester's own console
  • A message stream (MS) console
  • A status display (SD) console
The console must have master authority or RACF® approval to route something to an FC console.
ON THIS COMMAND
The name parameter was specified, but should not have been, on one of the following commands:
CONTROL S          CONTROL D
CONTROL E,N        CONTROL D,N
CONTROL E          CONTROL D,N,HOLD
CONTROL E,SEG      CONTROL D,PFK
CONTROL E,PFK      CONTROL N,PFK
CONTROL C,E
CONTROL C,I
CONTROL C,A

name OUTPUT ONLY
One of the following occurred:
  • An attempt was made to make a console full capability using the CONTROL V,USE = FC command. The console was an output only device.
  • An attempt was made to define areas using the CONTROL A,nn command on a console that is in message stream mode.
name SUBSYSTEM CONSOLE
An attempt was made to route messages to a console under the control of another subsystem.
name STATUS DISPLAY
An attempt was made to reroute messages to a status display console named name using the L=name-a parameter.
name SYSTEM CONSOLE
An attempt was made to issue a CONTROL S command on the system console.
name NOT IN PD MODE
An attempt was made to issue a CONTROL S command on the system console that was not in Problem Determination (PD) mode.
COMMAND ISSUED IS command
command is the text of the command that was originally entered.

System action

The system rejects the command.

Operator response

Depending on the message text, do the following:
name NOT AN AREA
Change the area specification. Enter the command again.
name NOT A CONSOLE
Change the console name and reenter the command.
name FULL CAPABILITY
Reenter the command by omitting the L=name-a parameter to have the response come to your own console, if desired.
ON THIS COMMAND
Enter the command again without the name parameter.
name OUTPUT ONLY
The console may be altered to status display mode by using the CONTROL V,USE=SD command. Then enter the CONTROL A,nn command again.
name SUBSYSTEM CONSOLE
name STATUS DISPLAY
Change the console name specification. Enter the command again.
name SYSTEM CONSOLE
Change the console name specification and enter the command again.
name NOT IN PD MODE
Change the system console to get into Problem Determination (PD) mode and enter the command again.

Source

Master scheduler

Module

IEE6703D, IEE6803D, IEE6903D, IEE7503D, IEE7703D, IEE8A03D, IEE8B03D, IEE2003D

Routing code

*

Descriptor code

5