IEE707I
cm yyy NOT EXECUTED

Explanation

Before processing command cm yyy, MVS™ presented the command to all subsystems that monitor commands. Based on the response returned, MVS did not process the command for one of the following reasons:
  1. One or more subsystems intentionally failed the command with a return code of 8.
  2. One or more subsystems issued a return code that was not valid.
  3. The command installation exit issued a return code of 8.
In the message text:
cm
The command entered.
yyy
The parameter field of the command.

System action

The system rejects the command.

Operator response

Contact the system programmer.

System programmer response

Determine why the subsystem or the installation exit routine rejected the command. The return code could be a valid, non-error return code.

Source

Master scheduler

Module

IEE0403D

Routing code

*

Descriptor code

5