IEE396I
INVALID CONTROL INTERVAL SIZE IN DATA SET dsname

Explanation

SMF initialization or SET SMF command processing found that the control interval size for SMF data set dsname is not the control interval size of the data sets that are already in use by the system.

Note: This message is issued instead of IEE953I only when an installation defines a data set name that does not use the SYS1.MANn naming convention.
In the message text:
dsname
The name of the SMF recording data set.

System action

SMF initialization or SET SMF command processing continues but ignores the dsname data set. If at least one valid SMF recording data set is available, recording continues. Otherwise, SMF will begin to buffer SMF data into storage until another data set becomes available. If a data set does not become available, SMF data will be lost.

System programmer response

Recreate the dsname data set using the access method services DEFINE utility and specify CONTROLINTERVALSIZE(xxxx), where xxxx is the control interval size for data sets that are already in use by the system. See z/OS MVS System Management Facilities (SMF) for information about creating SMF data sets.

Source

System Management Facilities (SMF)

Module

IEEMB822

Routing code

2,10

Descriptor code

5