IEE340E
DUMP DATA SET UNUSABLE: nn

Explanation

While writing an SVC dump, the system detected that the specified dump data set cannot be used to write the SVC dump for one of the following reasons:
  • The specified dump data set had been added with the DUMPDS command.
  • The specified dump data set was on a direct access storage device (DASD). Dynamic allocation failed to allocate the data set to the dump address space, and the data set is unusable.
In the message text:
nn
The 2-digit suffix of the DASD SYS1.DUMPnn data set name. For example, if the name is SYS1.DUMP17, xx is 17.

System action

The dump data set can no longer receive SVC dumps.

Operator response

Enter a DUMPDS ADD command to try to reconnect any lost dump data sets.

Source

Master scheduler

Module

IEAVTSDR, IEECB926, IEEMB810

Routing code

*

Descriptor code

5