IEC161I (return code 254)
rc[(sfi)]-ccc,jjj, sss,ddname,dev,ser,xxx, dsname,cat

Explanation

For general information about message IEC161I, see the explanation for return code 001.

Specific information for this return code: A TOLERATION warning, this reason code is given when an Open for output is issued for a data set whose attributes are obsolete or will be obsolete (ignored by AMS on a define) in a future release. The attributes are supported for currently defined data sets, and the message will not cause Open processing to terminate.

ccc = 026 - IDA0192Z: VSAM Open detected data set has more than 255 extents.

ccc = 780 - IDAV192Z: RLS Open detected data set has more than 255 extents.

If present, the SFI field is for use by IBM if further problem determination is required.
Table 1. SFI Reason Codes for Code 254
SFI Dec Value Description
01 Imbed
02 Keyrange
03 Replicate
04 Data set has more than 255 extent, but user did not turn on the VSAM extent constraint removal flag through data class.

System action

Open processing continues.

Programmer response

This is a warning that this data set has either:
  • Obsolete attributes, or
  • More than 255 extents. For SMS-managed volumes, user can set the extent constraint removal flag in the SMS data class to Y (yes) via the ISMF panels to remove the VSAM limit of 255 extents per component, or 255 extents per stripe for a VSAM striped data set.

Module

IDA0192Z

Routing code

11

Descriptor code

6