Explanation
At the end of removing a system from a sysplex,
the system enters this wait state. A hexadecimal reason code in register
15 indicates the reason why the system was removed:
- Code
- Explanation
- 01
- Communications task (COMMTASK) initialization could not establish
a member of the SYSMCS group because the maximum number of members
per cross-system coupling facility (XCF) group was reached.
- 02
- A recursive abend occurred while processing the console services
sysplex update task.
- 03
- A recursive abend occurred while processing the console services
cross-system update subtask.
- 05
- A recursive abend occurred while processing the console services
sysplex send data processor.
- 06
- A recursive abend occurred while processing the console services
sysplex receive data processor.
- 07
- A recursive abend occurred while processing the console services
cross-system service group exit.
- 08
- A recursive abend occurred while processing the console services
cross-system service message exit.
- 09
- A recursive abend occurred while processing the console services
sysplex command processor.
- 0A
- A recursive abend occurred when the system processed a message.
- 0B
- A recursive abend occurred while processing the console services
sysplex data queuer.
- 0C
- A recursive abend occurred while processing the console services
sysplex cleanup task.
- 0D
- Another system was unable to accept the system into the sysplex
because of a storage shortage.
- 0E
- A recursive abend occurred while the system was processing the
sysplex reply ID task.
- 0F
- A recursive abend occurred while processing the console services
sysplex recovery module.
- 11
- The system could not join the XCF SYSMCS2 group.
- 12
- The system could not create control members in the XCF SYSMCS2
group.
- 13
- The system could not initialize reply ID processing.
- 14
- Message cache could not be created.
- 15
- A recursive abend occurred while processing the console services
general-purpose task.
- 16
- Console definition initialization had an unrecoverable error.
- 18
- Data space could not be created.
- 19
- A bad return code was received from ALESERV ADD for a required
data space.
- 1D
- Both CNZ_MainDsm and CNZ_AuxDsm were damaged.
- 22
- A basic test of the CLT failed.
- 27
- A basic test of the CDUH failed.
- 30
- Console initialization could not establish appropriate serialization.
Message CNZ0006W has been issued with additional codes.
- 31
- Console migration detected inconsistencies in its data and cannot
let the migration continue. Message CNZ0006W has been issued with
additional error codes.
- 33
- Console migration task had an unrecoverable error.
- 34
- Essential console services function failed.
- 35
- The IPLing system does not support distributed mode.
- 36
- The IPLing system could not obtain console data from an existing
system in the sysplex. Message CNZ0008I identifies the existing system.
- 37 through 43
- During initialization, a module failed and could not be reattached
because module IEAVN701 had not finished its initialization.
System action
The system enters wait state X'087'.
System programmer response
Search problem reporting databases
for a fix for the problem. If no fix exists, contact the IBM® Support Center.
Source