Explanation
During system initialization, an error occurred
when the system tried to process the IEASYMxx parmlib member. A reason
code in register 15 explains the error:
- Code
- Explanation
- 00
- The system found a circular system symbol definition in
IEASYMxx. A circular system symbol definition is one that contains
another system symbol that is not resolved.
System Action: The
system issues message IEA012E, which further describes the error,
to the NIP console. The system enters a non-restartable wait state.
System
Programmer Response: See the system programmer response for message
IEA012E.
- 04
- The system found an error in IEASYMxx from which it could not
recover. The error occurred when the system tried to determine the
substitution text for a system symbol definition.
System Action: The
system issues message IEA013E, which further describes the error,
to the NIP console. The system enters a non-restartable wait state.
Operator
Response: Contact the system programmer. Provide the text of
message IEA013E.
System Programmer Response: See the
system programmer response for message IEA013E.
Source
Nucleus initialization program (NIP)