006 ExplanationDuring initial program load (IPL), an I/O error
occurred while IPL was reading from the SYSRES or IODF volume. The
error can be one or more of the following:
Note: One commonly seen cause for this problem is having
the nucleus in secondary extents. This problem has also been caused
by the nucleus containing a not-executable SVC. Browse SYS1.NUCLEUS
for any member with an attribute of NX.
System actionThe system enters a non-restartable wait state. Operator responseUse the hardware Problem Determination facilities to see if any errors occurred during the IPL process. If channel errors occurred, try configuring the channel paths offline and reipling the system. If the problem recurs, notify the system programmer. If the system programmer requests, obtain a standalone dump. System programmer responseSearch problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the stand-alone dump. SourceInitial program load (IPL) |