215 z/OS MVS System Codes SA38-0665-00 |
|
215 ExplanationThe error occurred during the processing of SVC 21 (STOW). This system completion code is accompanied by message IEC910I. Refer to the explanation of message IEC910I for complete information about the task that was ended and for an explanation of the return code in register 15. System actionThe STOW task recovery routine has been invoked. If the caller's DCB is in the caller's region, an attempt was made to trace it to the SYS1.TRACE data set. Operator responseStart a generalized trace facility (GTF) trace,
and re-create the problem. Reply to message AHL100A with:
On
the DD statement for the data set in error, specify:
System programmer responseIf the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the JCL and the program listing for the job. Programmer responseFor return codes 01, 02, and 03, verify that register 1 contained the correct DCB address prior to issuing SVC 21 and that the DCB has not been overlaid since being opened. For return code 04, verify that register 0 contained the correct parameter list address and that the list is within the caller's region prior to issuing SVC 21. SourceDFSMSdfp |
Copyright IBM Corporation 1990, 2014
|