z/OS MVS System Codes
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


025

z/OS MVS System Codes
SA38-0665-00

025

Explanation

The system was initiating a piece of work when a system error occurred. The reason code is in register 15 at the time the system issues the abend.
Code
Explanation
0002
The APPC Asynchronous_Manager callable service returned an error code to the initiator.
0003
The system found too many parameters on the job used to start the scheduler.
0004
The user tried to run the initiator under the initiator.
Others
The system found an internal error.

System action

The system writes an SVC dump, writes the logrec data set error records, and ends initiator processing.

System programmer response

Depending on the reason code, do the following:
Code
Response
0002
Search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center.
0003
Check the parameters on the job used to start the scheduler.
0004
Rename the program that is causing the abend.
For all other reason codes, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM Support Center. Provide the SVC dump and the logrec data set error records.

Source

Initiator/terminator

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014