IXGRPT1 analyzes the nearness of primary storage full condition for Logstreams
as follows. For DASDONLY Logstreams the type-3 completion is not defined and
will contain zero.
- Number of IXGWRITE invocations of completion type-1 (primary storage fullness
in “normal” range).
- Number of IXGWRITE invocations of completion type-2 (primary storage fullness
in “warning” range).
- Number of IXGWRITE invocations of completion type-3 (primary storage fullness
in “critical” range). This field will be zero for DASDONLY Logstreams.
- Number of times all log stream in structure offloaded during interval
- Number of times the structure full condition was actually reached.