This section contains one per logical control unit, described by triplet SMF79ASS.
Offsets | Name | Length | Format | Description | |
---|---|---|---|---|---|
0 | 0 | R79EID2 | 2 | EBCDIC | Logical control unit identifier. |
2 | 2 | R79EDST | 1 | binary | Data status
|
3 | 3 | 1 | Reserved. | ||
4 | 4 | R79EQSM | 4 | binary | Accumulated length of CU-HDR queue. |
8 | 8 | R79EQCT | 4 | binary | Number of entries placed on the CU-HDR queue. |
12 | C | R79EMCMN | 2 | binary | Minimum number of DCM managed channels used. |
14 | E | R79EMCMX | 2 | binary | Maximum number of DCM managed channels used. |
16 | 10 | R79EMCDF | 2 | binary | Defined number of DCM managed channels. |
18 | 12 | 2 | Reserved. | ||
20 | 14 | R79EPTM | 4 | binary | Accumulated path taken count for DCM managed channels. |
24 | 18 | R79EDPBM | 4 | binary | Accumulated director port busy count for DCM managed channels. |
28 | 1C | R79ECUBM | 4 | binary | Accumulated control unit busy count for DCM managed channels. |
32 | 20 | R79ECBTM | 4 | binary | Accumulated control unit busy delay time for DCM managed channels. |
36 | 24 | R79ECMRM | 4 | binary | Accumulated initial command response time for DCM managed channels. |
40 | 28 | R79ESBSM | 4 | binary | Accumulated switch busy count summation for DCM managed channels. |
44 | 2C | 8 | Reserved. | ||
52 | 34 | R79ECSST | 4 | binary | Channel subsystem wait time. |