Syntax examples for IECIOSxx

In Figure 1, the last two MIH records specify IOTIMING=00:00 and TIME=00:00. These specifications cancel MIH or I/O timing processing for the device numbers on the associated DEV keyword. Similarly, you can cancel hot I/O processing by specifying:
HOTIO DVTHRSH=0
Note: For 3800 devices, the default of 3 minutes for the MIH interval might not be sufficient. The recommended MIH interval for a 3800 is 5 minutes.
Figure 1. Syntax examples for IECIOSxx
HOTIO DVTHRSH=200
MIH STND=02:30,DASD=00:10,DEV=03C0,TIME=01:30
MIH DEV=(2E8-2FF,7300-7370),TIME=00:30
MIH 3851=15:00
HOTIO DFLT110=(BOX,BOX)
HOTIO DFLT111=(CHPK,BOX)
HOTIO DFLT112=(CHPK,BOX)
HOTIO SDFT110=(BOX,BOX)
HOTIO SDFT111=(CUK,BOX)
HOTIO SDFT112=(CUK,BOX)
HOTIO BOX_LP=(DASD,TAPE,UREC,COMM,CTC,GRAF,CHAR,ALL)
HOTIO BOX_LP=(DASD,TAPE,UREC)
HOTIO BOX_LP=(ALL)
MIH IOTIMING=00:12,DEV=(2E8-2FF,730-737)
MIH IOTIMING=00:12,DEV=200,MSGONLY=YES
MIH IOTDASD=10:00,MSGONLY=YES
MIH CTC=02:30,IOTIMING=00:00,DEV=(180-187,230,B10-B17)
MIH TIME=00:00,DEV=(180-187,230,B10-B17)
TERMINAL BOX_LP=(DASD)
TERMINAL BOX_LP=(TAPE,UREC)
TERMINAL BOX_LP=(ALL)
CTRACE(CTIIOS00)
CAPTUCB PROTECT=YES
FICON STATS=YES
STORAGE IOSBLKS=31
MIDAW=YES
HYPERPAV=YES
ZHPF=YES
Start of changeHYPERWRITE=YESEnd of change