- ACCODE(access code)
- Gives or changes the accessibility code for an ISO/ANSI output
tape data set, which protects it from unauthorized use. You can use
up to eight characters in the access code, but ISO/ANSI validates
only the first character. The ACCODE value can now be any
of the following 57 ISO/ANSI a-type characters: blank, uppercase letters
A-Z, numeric 0-9, or one of the special characters !*"%&'()+,-.⁄:;<=>?_
Note that Version 3 still supports only uppercase characters A-Z. Password
protection is supported for ANSI tape data sets under the PASSWORD/NOPWREAD
options of the LABEL parameter. Password access overrides any ACCODE
value if you use both options.
- ALTFILE(name)
- Specifies the name of the SYSIN subsystem data set that is to
be allocated. The name can be up to eight characters long. The system
uses this parameter primarily in the background.
This gives the
length in bytes of the average block.
- AVGREC(U|K|M)
- Determines the size of the average record block. You can use
these values:
- U
- Use the primary and secondary quantities as given in the SPACE
parameter.
- K
- Multiply primary space quantity and secondary space quantity
by 1024 (1 KB).
- M
- Multiply primary space quantity and secondary space quantity
by 1,048,576 (1 MB).
Use the AVGREC parameter to define a new data set when: - The units of allocation that are requested for storage space are
records.
- The primary and secondary space quantities used with the SPACE
parameter represent units, thousands, or millions of records.
When you use AVGREC with the SPACE parameter, the first
subparameter for the SPACE parameter must give the average record
length of the records.
Use the AVGREC parameter when you want
to show records as the units of allocation. You can also use this
parameter to override the space allocation defined in the data class
for the data set.
If SMS is not active, the system checks syntax
and then ignores the AVGREC parameter.
- BFALN(F|D)
- Gives the boundary alignment of each buffer:
- F
- Each buffer starts on a fullword boundary that might not be
a doubleword boundary.
- D
- Each buffer starts on a doubleword boundary.
If you do not use this parameter, the system defaults to
a doubleword boundary.
- BFTEK(S|E|A|R)
- Is the type of buffering that you want the system to use:
- S
- Simple buffering
- E
- Exchange buffering
- A
- Automatic record area buffering
- R
- Record buffering
BFTEK(R) is not compatible with partitioned data sets extended
(PDSE) and results in an error if used with the DSNTYPE(LIBRARY) parameter.
- BLKSIZE(value)
- Specifies the block size of the data control block (DCB) for
the data set. The maximum allowable decimal value for the block size
that is recorded in the DCB is 32,760. You can specify BLKSIZE for
NEW or MOD data sets.
For direct access storage
device (DASD) data sets: If you do not use BLKSIZE, the system
determines an optimal DCB block size for a new data set. You can create
the DCB block size in any of these ways: - The system determines the block size if SMS is active and you
do not assign the block size.
- You can assign the block size through the BLKSIZE parameter.
- You can use the LIKE parameter to obtain the block size from an
existing model data set.
- If you do not assign BLKSIZE or LIKE, the system can determine
the block size from the BLOCK parameter.
The block size that you assign for the DCB must be consistent
with the requirements of the RECFM parameter. If you use:
For PDSEs: - The system chooses the BLKSIZE value if you do not explicitly
specify it. If BLKSIZE is given, the system treats the BLKSIZE value
as the length of the simulated block. For create mode processing,
the logical record length is equal to the block size if LRECL is not
given. If you use LRECL, BLKSIZE must conform to the LRECL and RECFM
definitions. If you use:
- RECFM(F)
- BLKSIZE must equal LRECL
- RECFM(FB) or RECFM(FBS)
- BLKSIZE must be a multiple of LRECL
- RECFM(V) or RECFM(VB)
- BLKSIZE must be at least four bytes larger than LRECL
- RECFM(VBS)
- BLKSIZE must be at least eight bytes.
- For input or update processing, the block size must conform to
the currently defined record length. The BLKSIZE given when the data
set was created is the default. However, you can use any BLKSIZE if
it conforms to the record length definition.
- BUFL(buffer-length)
- Specifies the length, in bytes, of each buffer in the buffer
pool. Substitute a decimal number for buffer-length. The
number must not exceed 32,760. If you omit this parameter and the
system acquires buffers automatically, the BLKSIZE and KEYLEN parameters
supply the information needed to establish buffer length.
- BUFNO(number-of-buffers)
- Specifies the number of buffers that are assigned for data control
blocks. Substitute a decimal number for number-of-buffers. The number
must never exceed 255. You can be limited to a smaller number of buffers
depending on the limit established when the operating system was generated.
The following list shows how to get a buffer pool and the action required:
- Method
- Action
- BUILD macro instruction
- You must use BUFNO
- GETPOOL macro instruction
- The system uses the number that you assign for GETPOOL
- Automatically with BPAM, BSAM
- You must use BUFNO
- Automatically with QSAM
- You can omit BUFNO and accept two buffers
- BUFOFF({block-prefix-length|L})
- Defines the buffer offset. The block-prefix-length must
not exceed 99. L specifies the block prefix field is 4 bytes long
and contains the block length.
- BWO(TYPECICS|TYPEIMS|NO)
- Use this parameter if backup-while-open (BWO) is allowed for
the VSAM sphere. BWO applies only to SMS data sets and cannot be used
with TYPE(LINEAR). If BWO, LOG, or LOGSTREAMID is specified (or an
RLS cell exists for the data set), access from DFSMS/MVS 1.2
or a lower-level system is denied.
If BWO is specified
in the SMS data class, the specified BWO value is used as part of
the data set definition, unless BWO was previously defined with an
explicitly specified or modeled DEFINE attribute. - TYPECICS
- Use TYPECICS to specify BWO in a CICS® or
DFSMStvs environment. For RLS processing, this activates BWO processing
for CICS or DFSMStvs, or both. For non-RLS processing, CICS determines
whether to use this specification or the specification in the CICS FCT.
See the
CICS Transaction Server for z/OS Information Center at http://publib.boulder.ibm.com/infocenter/cicsts/v3r1/index.jsp.
Exception: If CICS determines
that it will use the specification in the CICS FCT,
the specification might override the TYPECICS parameter for CICS processing.
Abbreviation: TYPEC
- TYPEIMS
- Enables BWO processing for IMS™ data
sets. You can use this capability only with DFSMS 1.3 or higher-level
DFSMS systems. If you attempt to open a cluster that has the TYPEIMS
specification of a DFSMS 1.2 (or lower-level) system, the open will
not be successful.
Abbreviation: TYPEI
- NO
- Use this when BWO does not apply to the cluster.
Exception: If CICS determines
that it will use the specification in the CICS FCT,
the specification might override the NO parameter for CICS processing.
- DATACLAS(data-class-name)
- This is the 1- to 8-character name of the data class for either
SMS or non-SMS-managed data sets. If you do not assign DATACLAS for
a new data set and the storage administrator has provided an automatic
class selection (ACS) routine, the ACS routine can select a data class
for the data set. If you assign DATACLAS for an existing data set,
SMS ignores it. If SMS is not active, the system checks the syntax
and then ignores the DATACLAS parameter.
If you use the data class,
you do not need to list all the attributes for a data set. For example,
the storage administrator can provide RECFM, LRECL, RECORG, KEYLEN,
and KEYOFF as part of the data class definition. However, you can
override the DATACLAS parameter by explicitly defining the appropriate
parameters in the ALLOCATE command.
The data class defines
these data set allocation attributes: - Data set organization:
- Record organization (RECORG)
- Record format (RECFM)
- Record length (LRECL)
- Key length (KEYLEN)
- Key offset (KEYOFF)
- Space allocation
- Expiration date (EXPDT) or retention period (RETPD)
- Volume count (VOLUME)
- For VSAM data sets, the following:
- Index options (IMBED, or REPLICATE, or both)
- Control interval size (CISIZE)
RLS and DFSMStvs
support all CISIZE values, but a CISIZE value other than n*2K
consumes space in the coupling facility cache structure because a
2K data element does not have multiple coupling facilities. If CISIZE
is not used and the storage class is a nonblank cache set, the system
factors the default CISIZE.
- Percent free space (FREESPACE)
- Sharing options (SHAREOPTIONS)
- A cluster defined with IMBED cannot be opened for RLS or DFSMStvs
access.
- SHAREOPTIONS is assumed to be (3,3) when you use RLS or DFSMStvs.
Table 1. Data class
attributes for each data set organization. This table
lists data class attributes for each data set organization.Attributes |
KS |
ES |
RR |
LDS |
---|
CISIZE |
X |
X |
X |
X |
FREESPACE |
X |
|
|
|
IMBED |
X |
|
|
|
KEYLEN |
X |
|
|
|
KEYOFF |
X |
|
|
|
LRECL |
X |
X |
X |
|
REPLICATE |
X |
|
|
|
SHAREOPTIONS |
X |
X |
X |
X |
SPACE |
X |
X |
X |
X |
Volume Count |
X |
X |
X |
X |
- DEN({0|1|2|3|4})
- Gives the magnetic tape density as follows:
- 0
- 200 bpi/7 track
- 1
- 556 bpi/7 track
- 2
- 800 bpi/7 and 9 track
- 3
- 1600 bpi/9 track
- 4
- 6250 bpi/9 track (IBM 3420 Models 4, 6, and 8)
- DIAGNS(trace)
- Specifies the OPEN/CLOSE/End-of-Volume trace option that gives
a module-by-module trace of the OPEN/CLOSE/End-of-Volume work area
and your DCB.
- DIR(integer)
- Gives the number of 256 byte records for the directory of a
new partitioned data set. Use this parameter to allocate a new partitioned
data set.
- DSNTYPE(LIBRARY|PDS)
- Determines allocation of either a partitioned data set (PDS)
or a partitioned data set extended (PDSE). A PDSE must be SMS-managed.
If SMS is not active, the system checks the syntax and then ignores
the DSNTYPE parameter.
- LIBRARY
- A PDSE in record format
For more information on PDSE, see z/OS DFSMS Using Data Sets.
- DSORG(DA|DAU|PO|POU|PS|PSU)
- the data set organization as:
- DA
- Direct access
- DAU
- Direct access unmovable
- PO
- Partitioned organization
- POU
- Partitioned organization unmovable
- PS
- Physical sequential
- PSU
- Physical sequential unmovable
When
you allocate a new data set and do not use the DSORG parameter, these
occur: - If you assign a non-zero to the DIR parameter, DSORG defaults
to the partitioned organization (PO) option.
- If you do not assign a value to the DIR parameter, DSORG defaults
to the physical sequential (PS) option.
- The system does not store default DSORG information in the data
set until a program opens and writes to the data set.
With PDSEs, the PSU and POU options are incompatible
and result in an error if used with DSNTYPE(LIBRARY) while the data
set is open for output. If the data set is open for input or update,
PSU and POU are ignored.
To indicate the data set organization
for VSAM data sets, see RECORG.
- EROPT(ACC|SKP|ABE)
- The option you want to run if an error occurs when the system
reads or writes a record. The possible options are as follows:
- ACC
- Accept the block of records in which the error was found
- SKP
- Skip the block of records in which the error was found
- ABE
- End the task abnormally
- EXPDT(year-day)|RETPD(number-of-days)
- Expiration date or the retention period. The MGMTCLAS maximum
retention period, if given, limits the retention period in this parameter.
The system ignores these parameters for temporary data sets.
- EXPDT(year-day)
- This shows the data set expiration date. Include the year and
day as either:
- yyddd, where yy is
the last two digits of the year and ddd is
the three-digit number for the day of the year. The maximum for the
year is 99 (for 1999), and for the day is 366.
If you enter 99365
or 99366, the system retains your data sets permanently. Do not use
those dates as expiration dates. Use them as no-scratch dates only.
- yyyy/ddd, where yyyy is
the four-digit number for the year and ddd is
the three-digit number for the day of the year. This syntax requires
a slash. The maximum for the year is 2155. The maximum for the day
is 366.
If you use 1999/365 or 1999/366, the system retains your
data sets permanently. Do not use those dates as an expiration date.
Use them as no-scratch dates only.
EXPDT and RETPD are mutually exclusive.
- RETPD(number-of-days)
- Data set retention period, in days. It can be a one-digit to
four-digit decimal number.
RETPD and EXPDT are mutually exclusive.
- KEEP|CATALOG
- A command processor can modify the final disposition with these
parameters.
- KEEP
- This retains the data set by the system after step termination.
- CATALOG
- This retains the data set in a catalog after step termination.
- KEYLEN(bytes)
- This is the length, in bytes, of each of the keys
used to locate blocks of records in the data set when the data set
resides on a direct access device.
If an existing data set has
standard labels, you can omit this parameter and let the system retrieve
the key length from the standard label. If no source supplies a key
length before you enter an OPEN macro instruction, the system uses
zero (no keys). This parameter is mutually exclusive with TRTCH.
When
you want to define the key length or to override the key length defined
in the data class that the DATACLAS parameter specifies for the data
set, use KEYLEN. The number of bytes follows: - 1 to 255 for a record organization of key-sequenced (RECORG(KS))
- 0 to 255 for a data set organization of physical sequential (PS)
or partitioned (PO)
For PDSEs, you can use 0 or 8. Use 8 only when opening
the PDSE for input. Any other value results in an error.
- KEYOFF(offset)
- This shows the key position (offset) of the first byte of the
key in each record. Use it to define key offset or override the key
offset defined in the data class of the data set. It is only for a
key-sequenced data set (RECORG=KS).
Use KEYOFF parameter to allocate
both SMS-managed and non-SMS-managed data sets. If SMS is not active,
however, the system checks syntax and then ignores the KEYOFF parameter.
- LABEL(type)
- This selects the label processing, one of: SL, SUL, AL, AUL,
NSL, NL, LTM, or BLP, which correspond to the JCL label-types.
For
VSAM data sets, the system always uses SL, whether you define SL or
SUL or neither. NSL, NL, and BLP do not apply to VSAM data sets.
- LIKE(model-dsname)
- This names a model data set. The system uses these attributes
as the attributes of the new data set that is being allocated. The
model data set must be cataloged and must reside on a direct access
device. The volume must be mounted when you enter the ALLOCATE command.
Note: TSO/E naming conventions apply when you assign model-dsname.
When the ALLOCATE command assigns attributes to a new data
set, these attributes are copied from the model data set if SMS is
active: - AVGREC
- Size of average record block (kilobyte, megabyte)
- BLOCK, AVBLOCK,
-
- TRACKS, CYLINDERS
- Space unit
- DIR
- Directory space quantity
- DSORG
- Non-VSAM data set organization
- KEYLEN
- Key length
- KEYOFF
- Key offset
- LRECL
- Logical record length
- RECFM
- Record format
- RECORG
- VSAM data set organization
- SPACE
- Primary and secondary space quantities.
The system copies these attributes only if SMS is not
active: - BLKSIZE
- Block size
- EXPDT
- Data set expiration date
- OPTCD
- Optional services code (for ISAM data sets only)
- VSEQ
- Volume sequence number.
You can still use the LIKE parameter even if you do not
have an existing data set with the exact attributes you want to assign
to a new data set. You can use ALLOCATE attributes to override any
model data set attributes you do not want assigned to the new data
set.
When you use the LIKE parameter, these rules apply: - LIKE must be used with the NEW parameter; it cannot be used with
OLD, SHR, or MOD.
- Use LIKE with the DATASET parameter; it cannot be used with FILE.
- Only one dsname can be given in the DATASET parameter.
- The system does not copy the block size from the model data set
when SMS is active. If you do not show a block size in the ALLOCATE
command, the system determines an optimal block size to assign to
the data set.
- When SMS is active, attributes copied from the model data set
override attributes from the data class.
- If you allocate the new data set with a member name (indicating
a partitioned data set), the system prompts you for directory blocks
unless that quantity is either shown in the ALLOCATE command or defaulted
from the LIKE data set.
- If the new data set name is indicated with a member name, but
the model data set is sequential and you have not given the quantity
for directory blocks, you are prompted for directory blocks.
If you define the directory value as zero and the model
data set is a PDS, the system allocates the new data set as a sequential
data set.
The LIKE, REFDD, and USING operands are mutually
exclusive. For more information on the USING operand, see z/OS TSO/E Command Reference.
- LIMCT(search-number)
- This is the number of blocks or tracks that the system is to
search for a block or available space. The number must not exceed
32760.
- LRECL({logical-record-length|(nnnnnK|X)})
- This is the length, in bytes, of the largest logical record
in the data set. You must define this parameter for data sets that
consist of either fixed-length or variable-length records.
Use
the DATACLAS parameter in place of LRECL to assign the logical record
length. If SMS is active and you use LRECL, the system determines
the block size.
If the data set contains undefined-length records,
omit LRECL.
The logical record length must be consistent with
the requirements of the RECFM parameter and must not exceed the block
size (BLKSIZE parameter), except for variable-length spanned records.
If you use: - RECFM(V) or RECFM(V B), then the logical record length is the
sum of the length of the actual data fields plus four bytes for a
record descriptor word.
- RECFM(F) or RECFM(F B), then the logical record length is the
length of the actual data fields.
- RECFM(U), omit the LRECL parameter.
LRECL(nnnnnK) allows users of ANSI extended logical records
and users of QSAM "locate mode" to assign a K multiplier to the
LRECL parameter. nnnnn can be a number within
1-16384. The K indicates that the value is multiplied by 1024.
For
variable-length spanned records (VS or VBS) processed by QSAM (locate
mode) or BSAM, use LRECL (X) when the logical record exceeds 32,756
bytes.
For PDSEs, the meaning of LRECL depends upon the data
set record format: - Fixed-format records. For PDSEs opened for
output, the logical record length (LRECL) defines the record size
for the newly created members. You cannot override the data set control
block (DSCB) (LRECL); an attempt to do so will result in an error.
- Variable-format records. The LRECL is the
maximum record length for logical records that are contained in members
of the PDSE.
- Undefined-format records. The LRECL is the
maximum record length for records that are contained in members of
the PDSEs.
- MGMTCLAS(management-class-name)
- For SMS-managed data sets: This is the
1-to-8 character name of the management class for a
new data set. When possible, do not use MGMTCLAS. Allow it to default
through the ACS routines.
After the system allocates the data set,
attributes in the management class define the following items: - The migration of the data set. This includes migration both from
primary storage to migration storage, and from one migration level
to another in a hierarchical migration scheme.
- The backup of the data set. This includes frequency of backup,
number of versions, and retention criteria for backup versions.
If SMS is not active, the system checks the syntax and
then ignores the MGMTCLAS parameter.
- MAXVOL(count)
- This is the maximum number (1-255) of volumes upon which a data
set can reside. This number corresponds to the count field on the
VOLUME parameter in JCL. Use this to override the volume count attribute
defined in the data class of the data set.
If VOLUME and PRIVATE
parameters are not given, and MAXVOL exceeds UCOUNT, the system removes
no volumes when all the mounted volumes have been used, causing abnormal
termination of your job. If PRIVATE is given, the system removes one
of the volumes and mounts another volume in its place to continue
processing.
MAXVOL overrides any volume count in the data class
(DATACLAS) of the data set.
Your user attribute data set (UADS)
must contain the MOUNT attribute. Use of this parameter implies PRIVATE.
- NEW
- This creates a data set. For new partitioned data sets, you
must use the DIR parameter. If you assign a data set name, the system
keeps and catalogs a NEW data set. If you do not assign a data set
name, the system deletes the data set at step termination.
- NCP(number-of-channel-programs)
- This gives the maximum number of READ or WRITE macro instructions
that are allowed before a CHECK macro instruction is entered. The
number must not exceed 99 and must be less than 99 if a lower limit
was established when the operating system was generated. If you are
using chained scheduling, you must assign an NCP value greater than
1. If you omit the NCP parameter, the default value is 1.
- OPTCD(A,B,C,E,F,H,J,Q,R,T,W,Z)
- This lists optional services: (See also the OPTCD subparameter
of the DCB parameter in z/OS MVS JCL Reference for
details.)
- A
- Requires that the actual device addresses be presented in READ
and WRITE macro instructions.
- B
- Requires that the end-of-file (EOF) recognition be disregarded
for tapes.
- C
- Uses chained scheduling.
- E
- Asks for an extended search for block or available space.
- F
- Returns device address feedback from a READ or WRITE macro instruction
in the form it is presented to the control program.
- H
- Requests the system to check for and bypass. For more information,
see z/OS MVS JCL Reference.
- J
- Makes the character after the carriage control character the
table reference character for that line. The table reference character
tells TSO/E which character arrangement table to select when printing
the line.
- Q
- Translates a magnetic tape from ASCII to EBCDIC or from EBCDIC
to ASCII.
- R
- Requires relative block addressing.
- T
- Requests the user totaling facility.
- W
- Tells the system to perform a validity check when it wrties
data on a direct access device.
- Z
- Asks the control program to shorten its normal error recovery
procedure for input on magnetic tape.
You can use any or all the services by combining the characters
in any sequence, separating them with blanks or commas.
For
PDSEs, the system ignores OPTCD values other than OPTCD(J). OPTCD(J)
requires that the first data byte in the output data line is a 3800
table reference character.
- POSITION(sequence-number)
- This is the relative position (1-9999) of the data set on a
multiple data set tape. The sequence number corresponds to the data
set sequence number field of the label parameter in JCL.
- PRIVATE
- This assigns the private-volume use attribute to a volume that
is neither reserved nor permanently in resident. It corresponds to
the PRIVATE keyword of the VOLUME parameter in JCL.
If you do not
use VOLUME and PRIVATE parameters and MAXVOL exceeds UCOUNT, the system
removes no volumes when all the mounted volumes have been used, causing
abnormal termination of your job. If you use PRIVATE, the system
removes one of the volumes and mounts another volume to continue processing.
- PROTECT
- This RACF-protects the DASD data set or the first data set on
a tape volume.
- For a new permanent DASD data set, the status must be NEW or MOD,
treated as NEW, and the disposition must be either KEEP, CATALOG,
or UNCATALOG. With SMS, SECMODEL overrides PROTECT.
- For a tape volume, the tape must have an SL, SUL, AL, AUL, or
NSL label. The file sequence number and volume sequence number must
be one (except for NSL). You must assign PRIVATE as the tape-volume
use attribute.
The PROTECT parameter is not valid if a data set name is
not given, or if the FCB parameter or status other than NEW or MOD
is used.
- RECFM(A,B,D,F,M,S,T,U,V)
- This sets the format and characteristics of the records in the
data set. They must be completely described by one source only. If
they are not available from any source, the default is an undefined-length
record. See also the RECFM subparameter of the DCB parameter in z/OS MVS JCL Reference for
a detailed discussion.
Use these with the RECFM parameter: - A
- To show the record contains ASCII printer control characters
- B
- To indicate the records are blocked
- D
- For variable length ASCII records
- F
- For fixed length records.
- M
- For records with machine code control characters.
- S
- For fixed-length records, the system writes the records as standard
blocks (there must be no truncated blocks or unfilled tracks except
for the last block or track). For variable-length records, a record
can span more than one block. Exchange buffering, BFTEK(E), must not
be used.
- T
- The records can be written onto overflow tracks, if required.
Exchange buffering, BFTEK(E), or chained scheduling, OPTCD(C), cannot
be used.
- U
- The records are of undefined length.
- V
- Shows variable length records.
You must provide one or more values for this parameter.
For
PDSEs, these statements apply: - RECFM can be partially modified from the value that is saved in
the DSCB when creating members.
- In a PDSE that is created as fixed or fixed blocked, members must
always be created with fixed-length logical records. However, the
attribute of blocked might change between member creates. The first
record format assigned to the PDSE is the default for member creates.
The characteristic of blocked might not change during an open.
- Attempts to overwrite the record format characteristic of F, U,
or V with another value from that set causes a system error.
- RECFM(A) and RECFM(M) are compatible with PDSEs.
RECFM and RECORG are mutually exclusive.
- RECORG(ES|KS|LS|RR)
- Determines the organization of the records in a new VSAM data
set. To override the record organization defined in the data class
(DATACLAS) of the data set, use RECORG.
You can assign: - ES
- For a VSAM entry-sequenced data set
- KS
- For a VSAM key-sequenced data set
- LS
- For a VSAM linear space data set. You cannot access linear data
sets with VSAM record-level sharing (RLS) or DFSMStvs.
- RR
- For a VSAM relative record data set
If you do not use RECORG, SMS assumes a non-VSAM data set.
RECORG
and RECFM are mutually exclusive. To define the data set organization
for a non-VSAM data set, see DSORG.
Exception: You can use the RECORG parameter to allocate both SMS-managed
and non-SMS-managed data sets. If SMS is not active, however, the
system checks the syntax and ignores the RECORG parameter.
- REFDD(dsname)
- Specifies the name of an existing data set whose
attributes are copied to a new data set. The system copies these attributes
to the new data set:
- Data set organization:
- Record organization (RECORG)
- Record format (RECFM)
- Record length (LRECL)
- Key length (KEYLEN)
- Key offset (KEYOFF)
- Space allocation
The system does not copy the retention period (RETPD) or
expiration date (EXPDT) to the new data set.
LIKE and REFDD
are mutually exclusive.
Exception: You can use the REFDD parameter
to allocate both SMS-managed and non-SMS-managed data sets. If SMS
is not active, however, the system checks the syntax and then ignores
the REFDD parameter.
- RELEASE
- To delete unused space when the data set is closed.
If you
use RELEASE for a new data set with the BLOCK or BLKSIZE parameter,
then you must also use the SPACE parameter.
- REUSE
- Frees and reallocates a data set if it is currently
in use.
You cannot use the REUSE parameter to reallocate a data
set from a disposition of OLD to a disposition of SHR. However, you
can first free the data set with OLD and then reallocate it with SHR.
- ROUND
- Allocates space equal to one or more cylinders. Use this parameter
only when you request space in units of blocks. This parameter corresponds
to the ROUND parameter of the SPACE parameter in JCL.
- SECMODEL(profile-name[,GENERIC])
- Names an existing RACF® profile to copy to the discrete
profile. Use SECMODEL when you want a different RACF data
set profile from the default profile selected by RACF, or
when there is no default profile. The model profile can be any of
these profiles:
- RACF model profile
- RACF discrete data set profile
- RACF generic data set profile
Use GENERIC to state the profile name as a generic data set
profile.
The system copies this information from the RACF data
set profile to the discrete data set profile of the new data set: - OWNER indicates the user or group assigned as the owner of the
data set profile.
- ID is the access list of users or groups that are authorized to
access the data set.
- UACC gives universal access authority that is associated with
the data set.
- AUDIT|GLOBALAUDIT selects which access attempts are logged.
- ERASE indicates that the data set when it is deleted (scratched).
- LEVEL is the installation-defined level indicator.
- DATA is installation-defined information.
- WARNING indicates that an unauthorized access causes RACF to
issue a warning message, but allows access to the data set.
- SECLEVEL is the name of an installation-defined security level.
Exception: You can use the
SECMODEL parameter to allocate both SMS-managed and non-SMS managed
data sets. If SMS is not active, however, the system checks the syntax
and then ignores the SECMODEL parameter.
For
more information about RACF, see z/OS Security Server RACF Command Language Reference.
- SPACE(quantity[,increment])
- Allocates the amount of space for a new data set. If you omit
this parameter and:
- You are running MVS/ESA Version 3. The system uses
the IBM-supplied default value of SPACE(10,50) AVBLOCK (1000).
- You are running MVS/ESA SP Version
4. The system uses the IBM-supplied default value of SPACE(4,24) AVBLOCK
(8192).
However, your installation might have changed the default.
For more information about default space, see z/OS MVS Programming: Authorized Assembler Services Guide.To
have the system determine the amount of space, include the AVGREC
parameter in place of BLOCK, AVBLOCK, CYLINDERS, and TRACKS. To supply
your own space value, define one of the following: BLOCK( value),
BLKSIZE( value), AVBLOCK( value), CYLINDERS, or TRACKS.
The amount of space requested is determined as follows: - BLOCK(value) or BLKSIZE(value): The BLOCK or
BLKSIZE parameter's value is multiplied by the SPACE parameter's quantity.
- AVBLOCK(value): The AVBLOCK parameter's value is
multiplied by the SPACE parameter's quantity.
- CYLINDERS: The SPACE parameter's quantity is given in
cylinders.
- TRACKS: The SPACE parameter's quantity is given in tracks.
Use SPACE for NEW and MOD data sets. - quantity
- Allocates the initial number of units of space for a data set.
For a partitioned data set, a directory quantity is not necessary.
- increment
- This is the number of units of space to be added to the data
set each time the previously allocated space has been filled. You
must provide the primary quantity along with the increment value.
- BLOCK(value)
- Shows the average length (in bytes) of the records written to
the data set. The maximum block value used to determine space to be
allocated is 65,535. The block value is the unit of space that is
used by the SPACE parameter. A track or a cylinder on one device can
represent a different amount of storage (number of bytes) from a track
or a cylinder on another device. Determine the unit of space value
from the:
- Default value of (10 50) AVBLOCK(1000) if no space parameters
(SPACE, AVBLOCK, BLOCK, CYLINDERS, or TRACKS) are given.
- The BLOCK parameter.
- The model data set, if the LIKE parameter is used and BLOCK, AVBLOCK,
CYLINDERS, or TRACKS is not given.
- The BLKSIZE parameter if BLOCK is not used.
- AVBLOCK(value)
- This shows only the average length (in bytes) of the records
that are written to the data set.
- CYLINDERS
- Requests allocation in cylinders as the unit of space.
- TRACKS
- Requests allocation in tracks as the unit of space.
Exception: If you specify tracks for a VSAM data set, the space allocated
will be contiguous. For more information, see z/OS DFSMS Using Data Sets.
- STORCLAS(storage-class-name)
- For SMS-managed data sets: Gives the
1-to-8-character name of the storage class. When possible, allow STORCLAS
to default through the ACS routines established by your storage administrator.
Attributes assigned through storage class and the ACS routines replace
storage attributes such as UNIT and VOLUME. If SMS is not active,
the system checks the syntax and then ignores the STORCLAS parameter.
- TRTCH(C|E|ET|T)
- Selects the recording technique for 7-track tape as follows:
- C
- Data conversion with odd parity and no translation.
- E
- Even parity with no translation and no conversion.
- ET
- Even parity and no conversion. BCD to EBCDIC translation when
reading, and EBCDIC to BCD translation when writing.
- T
- Odd parity and no conversion. BCD to EBCDIC translation when
reading, and EBCDIC to BCD translation when writing.
The TRTCH and KEYLEN parameters are mutually exclusive.
- UCOUNT(count)|PARALLEL
- Shows device allocation.
- UCOUNT(count)
- This allocates the maximum number of devices, where count is
a value from 1-59.
If you do not use VOLUME and PRIVATE parameters
and MAXVOL exceeds UCOUNT, the system removes no volumes when the
mounted volumes have been used, causing abnormal termination of your
job. If you use PRIVATE, the system removes one of the volumes and
mounts another volume in its place to continue processing.
- PARALLEL
- Mounts one device for each volume given in the VOLUME parameter
or in the catalog.
- UNIT(type)
- Defines the unit type to which a file or data set is to be allocated.
You can list an installation-defined group name, a generic device
type, or a specific device address. If you do not supply volume information
(the system retrieves volume and unit information from a catalog),
the unit type that is coded overrides the unit type from the catalog.
This condition exists only if the coded type and class are the same
as the cataloged type and class.
For VSAM data sets, use the AFF
subparameter carefully. If the cluster components and the data and
its index reside on unlike devices, the results of UNIT=AFF are unpredictable.
When
you allocate a new SMS-managed data set, the system ignores the UNIT
parameter. The system determines the UNIT and VOLUME from the storage
class associated with the data set. Use UNIT only if you want to allocate
a non-SMS-managed data set to a specific unit type.
If the
storage administrator has set up a default unit under SMS regardless
of whether the data set is SMS-managed, you do not have to use UNIT.
If you do not, the system determines the default UNIT for both SMS-managed
and non-SMS-managed data sets.
- VOLUME(serial-list)
- This is the serial number of an eligible direct access volume
on which a new data set is to reside or on which an old data set is
located. If you use VOLUME for an old data set, the data set must
be on the specified volume for allocation to take place. If you do
not include VOLUME, the system allocates new data sets to any eligible
direct access volume. The UNIT information in your procedure entry
in the user attribute data set (UADS) determines eligibility. You
can use up to 255 volume serial numbers.
For VSAM data sets, you
need to use this subparameter carefully. For more information about
DD parameters to avoid when processing VSAM data sets, see z/OS MVS JCL User's Guide before
you use the VOLUME subparameter REF, volume-sequence-number,
or volume-count.
When you allocate new SMS-managed
data sets, you can let the ACS routines select the volume for you.
The ACS routines assign your data set to a storage class that contains
attributes such as VOLUME and UNIT. You can allocate your data set
to a specific volume only if your storage
administrator has stated GUARANTEED SPACE=YES in the storage class
assigned to your data set. The volume serial
numbers you provide might then override the volume serial numbers
used by SMS. If space is not available on the given volume, however,
your request is not successful.
Abbreviation:
VOL
- VSEQ(vol-seq-number)
- This locates which volume (1-255) of a multivolume begins data
set processing. This parameter corresponds to the volume sequence
number on
the VOLUME parameter in JCL. Use VSEQ only when the data set is a
cataloged data set.
|