ABEND |
Use for a system abend in a context that does not relate to
a specific code |
ABENDnnn |
Use ABENDnnn for a system abend (for
example, ABEND0C1, ABEND0F4) |
ABENDUnnnn |
Use ABENDUnnnn for a user abend (for
example ABENDU0845) |
*Access method services |
Use IDCAMS |
*APAR nnnnn |
Use OYnnnnn (for example, OY12345) |
*CA split |
Use CI/CA SPLIT |
CCxx |
Condition code (exactly as the system presents it) |
CHAN |
Channel |
*CI split |
Use CI/CA SPLIT |
CI/CA SPLIT |
Control interval and/or control area split |
*Catalog |
Use VSAMCAT |
*Catalog Management |
Use CATMGT |
CATMGT |
Catalog management function of VSAM |
*Checkpoint/Restart |
Use CHKPT |
CHKPT |
Checkpoint/Restart |
CMD REJ |
Command reject (hardware sense bit) |
*Command reject |
Use CMD REJ |
*Condition code |
Use CCxx (exactly as the system presents
it) |
*Control block |
Use the standard control block identifier, for example, DCB,
AMB, RPL, and so forth |
COREOVERLAY |
Main storage overlay or overlaid |
CPC |
Channel program check (hardware sense bit) |
CREGnn |
Control register |
*Cross-Memory mode |
Use XMM |
DCK |
Data check (hardware sense bit) |
*Data Language/I function of IMS™ |
DL/I |
*Device Type nnnn |
Use D/Tnnnn (for example, D/T3380) |
DInnnnnnnn |
DADSM diagnostic information (nnnnnnnn is
four hex bytes) |
D/Tnnnn |
Device type related to problem, if only one device type experiences
the failure |
*Duplicate Records |
Use DUPREC |
DUPREC |
Failure causes duplicate records in a data set |
EQC |
Equipment check (hardware sense bit) |
ESDS |
Entry sequenced data set |
*Format-n DSCB |
Use FnDSCB |
FnDSCB |
Type of DSCB (n is a decimal digit,
for example F4DSCB) |
*Hardware program check |
Use PROGCK |
*High-Impact Pervasive problems |
Use HIPER |
ICC |
Interface control check (hardware sense bit) |
IDCAMS |
Access method services |
Incorrect output, unrelated to performance degradation |
Use INCORROUT |
INDEX |
Data set index (used when describing data set damage) |
*Instruction |
Use INST/xxx |
INST/xxx |
Failing instruction mnemonic (for example, INST/MVCL) |
Initial Program Load of the system |
Use IPL |
KSDS |
Key sequenced data set |
*Label xxxxxx |
Use LBLxxxxxx (for example, LBLNAME01).
Note: For PLS-generated labels, omit the @.
|
LBLxxxxxx |
Program listing statement label xxxxxx |
LDS |
Linear data set |
*Lost records |
Use MISSREC |
*Manuals |
Use manual order number without hyphens (for example, GC264149) |
*Master catalog |
Use MASTCAT or MCAT |
MASTCAT |
Master catalog (MCAT is also permissible) |
MCAT |
Master catalog (MASTCAT is also permissible) |
*Missing records |
Use MISSREC |
MISSREC |
Missing records from a data set |
*Model number (hardware device) |
Use D/T with a three-digit model number (D/T3380 023) |
NCA |
Not capable (tape hardware sense bit) |
*No record found |
Use NRF |
NRF |
No record found in data set |
*OPEN/CLOSE/EOV |
Use O/C/EOV |
O/C/EOV |
OPEN/CLOSE/End-of-Volume (common) subcomponent of DFSMSdfp |
*Out of sequence |
Use OUTOFSEQ |
OUTOFSEQ |
Record keys out of sequence |
OVR |
Overrun (hardware sense bit) |
PROGCKxx |
Hardware program check (for example, PROGCK01, PROGCK0C) |
*PTF nnnnn |
Use UYnnnnn (for example, UY12345) |
*Publications |
Do not use hyphens (for example, GC264149) |
*Return Code, decimal value |
Use RCnn (exactly as the system presents
it, for example RC04, RC12) |
RCnnn |
Return code, reason code, function code, error code, and so
forth (exactly as the system presents it) |
*Reason code, hex value |
RSxxxxxxxx (for example, RS0418003C).
Use RSNxxxxxxxx for PDSE |
*Record Management |
Use RECMGT |
RECMGT |
Record management function of VSAM |
*Record Management Trace |
Use RMTRACE |
*Record-Level Sharing |
Use RLS or VSAMRLS |
*Registers |
Use REGnn for general purpose registers,
CREGnn for control registers, and FPREGnn for
floating point registers, where (nn is either
one or two decimal digits with leading zeros.) |
REGnn |
General purpose register (use two decimal digits, for example,
REG02 or REG14) |
*Release Level |
Use Rnnn |
RLS |
Record-Level Sharing |
RMTRACE |
Record management trace facility of VSAM |
RPLFDBWDnnnnnnnn |
RPL feedback-word (nnnnnnnn is four
hexadecimal bytes) |
RRDS |
Relative record data set |
*Share options |
Use SHROPT |
SHROPT |
VSAM share options |
SKC |
Seek check (DASD hardware sense bit) |
*Storage Overlay |
Use COREOVERLAY |
*Supervisor Call |
Use SVCnn or 0Ann |
SVCnn |
Supervisor call instruction (nn is
decimal, no leading zeros). (See 0Ann for
hexadecimal |
UCAT |
User catalog (USERCAT is also permissible) |
UCK |
Unit check (hardware sense bit) |
UEX |
Unit exception (hardware sense bit) |
USERCAT |
User catalog (UCAT is also permissible) |
*User catalog |
Use UCAT or USERCAT |
*Volume table of contents |
Use VTOC |
*VSAM Record-Level Sharing |
Use VSAMRLS or RLS |
VSAMCAT |
Catalog |
VSAMRLS |
VSAM Record-Level Sharing |
VTOC |
DASD volume table of contents |
WAIT |
Task or job waiting for an event |
WAITxxx |
System disabled wait with hex code of 'xxx' (for example, WAIT04F) |
WRI |
Write inhibit switch should be checked (DASD hardware sense
bit) |
*Wrong record |
Use WROREC |
WROREC |
Wrong record in data set |
0Ann |
Supervisor call instruction (nn is
hexadecimal) |