Use this definition with channel PU interfaces (ESCON, BCCA, or CADS) to communicate with NCPROUTE using IP over CDLC devices with the MVS™ host.
The following example shows channel PU interface definitions with the ESCON channel type:
**********************************************************************
* PHYSICAL ESCON CHANNEL DEFINITIONS *
**********************************************************************
*
A04PSOC1 GROUP LNCTL=CA,MONLINK=NO,NPACOLL=NO,XMONLNK=YES
SPEED=144000000,SRT=(32768,32768)
*
A04S2240 LINE ADDRESS=2240
A04P2240 PU ANS=CONTINUE,PUTYPE=1
*
**********************************************************************
* LOGICAL ESCON CHANNEL DEFINITIONS *
**********************************************************************
*
A04PSOCB GROUP LNCTL=CA,PHYSRSC=A04P2240,NPACOLL=NO,
DELAY=0.2,MAXPU=16,MODETAB=AMODETAB,
DLOGMOD=INTERACT,SPEED=144000000,
SRT=(21000,20000),PUDR=YES,
TIMEOUT=150.0,CASDL=0.0
*
A04LSOC2 LINE ADDRESS=NONE,HOSTLINK=1
A04L2S1 PU ADDR=01,PUTYPE=1,ARPTAB=(10,,NOTCANON),
INTFACE=SOCPU1
A04L2S2 PU ADDR=02,PUTYPE=1,ARPTAB=(10,,NOTCANON),
INTFACE=SOCPU2