EZD1311I

z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
SC27-3655-01

EZD1311I
SYSPLEX DISTRIBUTOR CONTROL CONNECTION TO DESTINATION IP ADDRESS ip_addr CLOSED DUE TO A PROTOCOL ERROR WITH RETURN CODE internal_retcode.

Explanation

The control connection to the non-z/OS target has been closed as the result of a protocol error. The non-z/OS target cannot be used as a target for distributed connections.

In the message text:
ip_addr
The IP address of a distributed non-z/OS target.
internal_retcode
The internal return code that was set by the function that detected the protocol error.

System action

TCP/IP continues.

Operator response

Contact the system programmer.

System programmer response

Contact the IBM® software support services with the TCP/IP profile and the system log.

User response

Not applicable.

Problem determination

Not applicable.

Source

z/OS® Communications Server TCP/IP: Sysplex Distributor

Module

EZBXFSUB

Routing code

2,8

Descriptor code

12

Automation

This message is written to the system console. This message is a good candidate for automation. Automation can allow you to monitor the status of sysplex distributor control connections to non-z/OS targets.

Example

EZD1311I SYSPLEX DISTRIBUTOR CONTROL CONNECTION TO DESTINATION IP ADDRESS   9.42.105.53 CLOSED DUE TO 
         PROTOCOL ERROR WITH RETURN CODE 00000016