z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZD1292I

z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
SC27-3655-01

EZD1292I
No active EXPLICITBINDPORTRANGE is available from this stack

Explanation

This message is issued in response to a DISPLAY TCPIP,tcpname,SYSPLEX,PORTS command. The active explicit bind port range is not available to be displayed from this stack either because explicit bind port range processing is not enabled for this stack or this stack does not have access to the sysplexports coupling facility structure.

System action

TCP/IP continues

Operator response

Issue the DISPLAY TCPIP,tcpname,SYSPLEX,PORTS command, specifying a stack that has explicit bind port range processing enabled, or issue a DISPLAY NET,STATS,TYPE=CFS,STRNAME=sysplexports_structure_name command on a VTAM® node that is connected to the sysplexports structure. See the information about the GLOBALCONFIG statement in z/OS Communications Server: IP Configuration Reference for information about enabling the EXPLICITBINDPORTRANGE parameter. See the information about the DISPLAY STATS command information in z/OS Communications Server: SNA Operation for information about displaying sysplexport structure data.

System programmer response

None.

User response

Not applicable.

Problem determination

Not applicable.

Source

z/OS® Communications Server TCP/IP

Module

EZBXFIO2

Routing code

Not applicable.

Descriptor code

Not applicable.

Example

Not applicable.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014