EZD0905I IKE configuration file fname does not
contain an IkeConfig statement ExplanationThe Internet Key Exchange (IKE) daemon configuration file must specify an IkeConfig statement to indicate that there are IKE configuration parameters. fname is the name of the IKE daemon configuration file. System actionIf the error occurs during IKE startup, IKE daemon configuration file processing ends, and the IKE daemon ends. If the error occurs due to a MODIFY REFRESH command, IKE daemon configuration file processing ends, but the IKE daemon remains active. IKE configuration retains all values prior to the MODIFY REFRESH command. Operator responseEnsure that IkeConfig statement is specified in the configuration file. See the information about the IKE daemon in z/OS Communications Server: IP Configuration Reference for more information about the IkeConfig statement and IKE daemon configuration file. System programmer responseNone. Moduleike_config.cpp Procedure nameNone. |