EZD0030I

z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
SC27-3655-01

EZD0030I
DISPLAY OSAINFO FAILED FOR name - reason

Explanation

The DISPLAY TCPIP,,OSAINFO request could not be processed for one of the reasons listed below.

In the message text:
name
The INTFNAME value specified on the DISPLAY TCPIP,,OSAINFO command.
reason
The reason for the error. Possible values are:
LINK OR INTERFACE DOES NOT EXIST
The LINK or INTERFACE name does not exist.
LINK OR INTERFACE DOES NOT SUPPORT DISPLAY OSAINFO
The LINK or INTERFACE does not support the DISPLAY TCPIP,,OSAINFO command.
LINK OR INTERFACE NOT ACTIVE
The OSA-Express is not currently active.
COMMAND ALREADY IN PROGRESS
A DISPLAY TCPIP,,OSAINFO command is already in progress for the OSA-Express.
STORAGE NOT AVAILABLE
Storage required to complete the DISPLAY TCPIP,,OSAINFO request could not be obtained.
COMMAND TIMED OUT
The OSA-Express has taken too long to reply with the information.

System action

Processing of the DISPLAY TCPIP,,OSAINFO command is discontinued.

Operator response

Not applicable.

System programmer response

For persistent COMMAND TIMED OUT failures, obtain a TCP/IP CTRACE with the VTAM® option and contact IBM® software support services.

User response

Follow the procedure described in the Problem Determination and re-submit the DISPLAY TCPIP,,OSAINFO command.

Problem determination

  • If the reason value is LINK OR INTERFACE DOES NOT EXIST, issue the DISPLAY TCPIP,,NETSTAT,DEVLINKS
  • If the reason value is LINK OR INTERFACE NOT ACTIVE, start the LINK or INTERFACE.
  • If the reason value is LINK OR INTERFACE DOES NOT SUPPORT DISPLAY OSAINFO, either the LINK or INTERFACE is not OSA-Express or the OSA-Express must be upgraded prior to issuing this command. DISPLAY TCPIP,,OSAINFO is limited to OSA-Express3 ethernet features in QDIO mode (CHPID type OSD, OSM, or OSX).
  • If the reason value is COMMAND ALREADY IN PROGRESS, wait for the previous command to complete.
  • If the reason value is STORAGE NOT AVAILABLE, determine and fix the reason for the storage shortage. See the information about the diagnosing storage abends and storage growth in z/OS Communications Server: IP Diagnosis Guide for more information about storage problems.
  • If the reason value is COMMAND TIMED OUT, the OSA-Express is either extremely busy or an internal error occurred. If the failure persists contact the system programmer.

Source

z/OS® Communications Server TCP/IP

Module

EZBIFIND, EZBIFDOB

Routing code

*

Descriptor code

*

Automation

Not applicable.

Example

EZD0030I DISPLAY OSAINFO FAILED FOR NSQDIO11 - LINK OR INTERFACE DOES NOT  EXIST