MODULE loadmod COULD NOT BE LOADED. command PROCESSING IS STOPPED. ABEND CODE abncode REASON CODE rsncode.

Explanation

loadmod
name of the load module
command
an SMP/E command or program or blank
abncode
system abend code
rsncode
system reason code

The load module could not be loaded, possibly because the indicated load module was not found in the link list library.

System action

Command or application processing stops.

Programmer response

Ensure the library containing the indicated load module was correctly specified in the system link list and that indicated library does contain the requested load module.

See z/OS MVS System Codes, SA38-0665, for an explanation of the system abend and reason codes.