LIBRARY library IS SEQUENTIAL YET enttype1 entname1 IS ALREADY ASSIGNED TO IT. SMP/E PROCESSING HAS FAILED FOR enttype2 entname2 IN SYSMOD sysmod.

Explanation

library
ddname of the sequential library
enttype1
already assigned data element type
entname1
already assigned data element name
enttype2
data element type
entname2
data element name
sysmod
name of SYSMOD supplying the data element

The data element being APPLIED, ACCEPTED, or RESTORED has the specified library, which is a sequential data set. Only one element can exist in a sequential data set, and there is already one assigned to it.

System action

Processing fails for the SYSMODs containing the data elements.

Programmer response

Check the DDDEF entry or DD statement for the specified library to ensure that it specifies the correct data set. If the data set is correct, verify that the data set was allocated with the correct organization. If it should have a partitioned organization, change the allocation and rerun the command.

If the data set should be sequential, verify that the DDNAME for the specified data element is correct. If it is incorrect, correct the SYSLIB or DISTLIB subentry, and rerun the command.