Activate software and hardware configuration changes
The following procedure describes how to change the software and
hardware configuration for one or more systems in a sysplex.
- Select one or more systems from the Active Sysplex Member List
and the Activate software and hardware configuration action
from the context menu (or action code a ). The Activate
Hardware and Software Configuration panel is displayed.
Figure 103. Activate Hardware and Software Configuration
*--------------- Activate Hardware and Software Configuration ---------------*
| Row 1 of 2 More: > |
| |
| Specify or revise the values for activation, then press Enter. |
| |
| IODF to be activated: SYS4.IODF71 |
| |
| System Processor Partition Config. EDT -FORCE Option- Switch Test |
| Name ID + Name ID + ID + DEVICE CANDID. IOCDS + Only |
| IRD4 ECL2 IRD4 MVSVM 00 No No __ Yes |
| IRD6 R35 IRD6 MVSVM 00 No No __ Yes |
| ***************************** Bottom of data ***************************** |
*----------------------------------------------------------------------------*
The systems you have selected are shown together with the
associated processor IDs.
Empty Processor
ID:
If the Processor ID field is empty,
prompt for the processor IDs and select the actual one.
Empty Configuration or EDT ID:
If
the Config. ID and the EDT ID fields are
empty, it is an indication that the ID of the currently active configuration
is not defined in the IODF to be activated. Prompt for the new ID.
Updating the Processor ID, the Config. ID or
the EDT ID fields might be required if your IODF to
be activated contains IDs different from those displayed as default
IDs.
Switch IOCDS:
In
the Switch IOCDS column, you can define the IOCDS name
used for the next POR.
- On the Activate Hardware and Software Configuration panel, update
the fields of one or more systems. It is recommended that you first
test an activation before you dynamically activate a configuration.
If
you plan to delete a device for a specific system, specify Yes in the FORCE DEVICE field
of that system. If you plan to remove a partition from the access
or candidate list of a channel path belonging to a specific system,
specify Yes in the FORCE
CANDID. field of that system.
- After updating the panel, press the Enter key. The Active Sysplex
Member list will be displayed again, but now the Active
IODF fields have changed for the affected systems and now contain
the name of the IODF to be activated. If you have defined different
processor IDs, configuration IDs or EDT IDs, and you have activated
their configurations, these fields also have been changed.
- Select a system and the View messages action
from the context menu (or action code m ). The messages
returned from that system as the result of the activation request
are displayed.
- If you do not need the messages any longer, you can delete them
by using the option Delete messages (or
action code d ).
If Dynamic Activation Fails
Refer to If dynamic activation fails for information on how to proceed,
if your activation has been rejected.
|