Issue the CQUERY command with the PATHS option to query the status
of all PPRC paths established for a volume’s storage control.
You can request formatted or unformatted output, as
described in Formatted and unformatted output.
In a Multi-Target Mirror
environment, that is, Multi-Target is supported by the microcode and ENABLE(PPRCMT) is specified in
the DEVSUPxx member of PARMLIB, the formatted output reflects all of the secondary control
units that are defined to the primary, which can be up to 16.
Note: - CQUERY command output in the SYSLOG can contain a connection code
at the end of the header message and at the beginning of each of the
lines associated with that connection code. The system generates this
code for any multiline WTO.
- The CQUERY PATHS and VOLUME reports may show incorrect information
for the secondary subsystem WWNN in the case where that secondary
is located on an ESS that does not have LIC 2.3 installed.
In this case the WWNN information is not reported back correctly from
the primary storage control. Do not use this WWNN information to attempt
to set up paths or devices on that secondary subsystem. This could
lead to an inadvertent establish on the wrong device as a secondary.
Note:
The following command queries paths established for volume 0F40:
CQUERY DEVN(X'0F40') PATHS