IBM Tivoli Storage Manager, Version 7.1

FMV3404W

An error occured reading volume name.

Explanation

The named volume could not be read. Examples of why this can occur include, but are not limited to: the data being read is outside the valid range of the volume, or the device is locked by another application. The operating system error code shown in the message indicates the specific reason for the failure.

System action

If server-free data movement is used, processing continues using non-server-free data movement. Otherwise processing stops.

User response

Use your operating system's tools to obtain the description of the error code. Also check the error log for any other messages that might indicate a reason for the failure. Try to correct any indicated problems, then try the operation again. If the problem persists, contact IBM® technical support for further assistance.