Tracing in a CMAS
The CICS® internal trace facilities must always be active in a CMAS.
When a CMAS initializes, CICSPlex® SM ensures that the CICS trace facility is active and the trace table is large enough. The minimum trace table settings, along with the CICS system initialization parameters that you must use, are in the following table:
Trace variable | Required setting | System initialization parameter option |
---|---|---|
Internal trace | On | INTTR=ON |
Trace table size | 12 MB minimum | TRTABSZ=12288 |
Main trace | Off | SYSTR=OFF |
User trace | On | USERTR=ON |
If the CICS trace facilities cannot be activated with these settings, CMAS initialization is canceled and you receive an error message.
Additionally, the CICS AUXTRACE facility should be active (for user records only) in a CMAS. If this facility is not active when a problem occurs, it might be necessary to re-create the problem with the facility turned on.