System termination program exit XSTERM
The XSTERM exit could be used to output final statistics to your statistics SMF data sets, and to close them. Note that CICS® VSAM and BDAM data sets have already been closed by CICS file control before the exit is invoked.
- When invoked
- During the second quiesce stage of a normal system shutdown, immediately before the transient data and temporary storage buffers are cleared. The exit is not invoked during an IMMEDIATE shutdown.
- Exit-specific parameters
- None.
- Return codes
-
- UERCNORM
- Continue processing.
- XPI calls
- All other XPI calls except WRITE_JOURNAL_DATA can be used. However, their use is not recommended, because they could cause the task to lose control, thus allowing another task to write more monitoring data.