User exit routines

This table lists the user exit routines trace points, including the trace ID, the module name, the trace level, the trace type, and the data returned by the trace point. User exit routine trace points range from AP D500 to AP D532.

Table 1. User exit routines
Point ID Module Lvl Type Data
AP D500 DFHUEH UE 1 Before exit call
1
Exit ID
2
Exit program name
AP D501 DFHUEH UE 1 After exit call
1
Return code
2
Address of EPB
3
Exit program name
AP D502 DFHSUEX UE 1 Before exit call
1
Exit ID
2
Exit program name
AP D503 DFHSUEX UE 1 After exit call
1
Return code
2
Address of EPB
3
Exit program name
AP D504 DFHSUEX Exc Invalid function
1
DFHSUEX parameter list
AP D505 DFHSUEX Exc Invalid format
1
DFHSUEX parameter list
AP D506 DFHSUEX Exc Clear error during recovery
1
PGEX_RESPONSE
2
PGEX_REASON
3
Program token
4
PLCB
AP D507 DFHSUEX Exc Prepare exit error
1
PGEX_RESPONSE
2
PGEX_REASON
3
Program token
4
PLCB
AP D508 DFHSUEX Exc Clear exit error
1
PGEX_RESPONSE
2
PGEX_REASON
3
Program token
4
PLCB
AP D509 DFHUEH Exc Prepare exit error
1
PGEX_RESPONSE
2
PGEX_REASON
3
Program token
4
PLCB
AP D50A DFHUEH Exc Clear exit error
1
PGEX_RESPONSE
2
PGEX_REASON
3
Program token
4
PLCB
AP D50B DFHUEH Exc Clear error during recovery
1
PGEX_RESPONSE
2
PGEX_REASON
3
Program token
4
PLCB
AP D50C DFHSUEX Exc Switch subspace call failed
1
DFHSUEX parameter list
AP D50D DFHUEH UE 1 Handle abend exit modified address
1
Branch address
2
Program name
AP D50E DFHUEH Exc Recovery
1
DFHUEPAR parameter list
2
Kernel error data
AP D50F DFHSUEX Exc Recovery
1
DFHSUEX parameter list
2
Kernel error data
3
Name of program in error
AP D510 DFHAPEX AP 1 Entry
1
DFHAPEX parameter list
AP D511 DFHAPEX AP 2 Entry part 1 Up to 200 bytes of each exit parameter:
1
Exit parameter 1
2
Exit parameter 2
3
Exit parameter 3
4
Exit parameter 4
5
Exit parameter 5
6
Exit parameter 6
7
Exit parameter 7
AP D512 DFHAPEX AP 2 Entry part 2 Up to 200 bytes of each exit parameter:
1
Exit parameter 8
2
Exit parameter 9
3
Exit parameter 10
4
Exit parameter 11
5
Exit parameter 12
6
Exit parameter 13
7
Exit parameter 14
AP D513 DFHAPEX Exc Invalid function
1
DFHAPEX parameter list
AP D514 DFHAPEX Exc Invalid format
1
DFHAPEX parameter list
AP D515 DFHAPEX AP 1 Exit
1
DFHAPEX parameter list
AP D516 DFHAPEX AP 2 Exit part 1 Up to 200 bytes of each exit parameter:
1
Exit parameter 1
2
Exit parameter 2
3
Exit parameter 3
4
Exit parameter 4
5
Exit parameter 5
6
Exit parameter 6
7
Exit parameter 7
AP D517 DFHAPEX AP 2 Exit part 2 Up to 200 bytes of each exit parameter:
1
Exit parameter 8
2
Exit parameter 9
3
Exit parameter 10
4
Exit parameter 11
5
Exit parameter 12
6
Exit parameter 13
7
Exit parameter 14
AP D518 DFHAPEX Exc Change mode request failed
1
DFHAPEX parameter list
AP D519 DFHAPEX Exc Invalid exit
1
DFHAPEX parameter list
AP D51A DFHAPEX Exc User exit program failed, part 1 Up to 200 bytes of each exit parameter:
1
Exit parameter 1
2
Exit parameter 2
3
Exit parameter 3
4
Exit parameter 4
5
Exit parameter 5
6
Exit parameter 6
7
Exit parameter 7
AP D51B DFHAPEX Exc User exit program failed, part 2 Up to 200 bytes of each exit parameter:
1
Exit parameter 8
2
Exit parameter 9
3
Exit parameter 10
4
Exit parameter 11
5
Exit parameter 12
6
Exit parameter 13
7
Exit parameter 14
AP D51C DFHAPEX Exc Call to invoke user exit program failed
1
DFHAPEX parameter list
AP D51F DFHAPEX Exc Recovery
1
DFHAPEX parameter list
2
Kernel error data
AP D520 DFHAPEX AP 2 Entry part 3 Up to 200 bytes of each exit parameter:
1
Exit parameter 15
2
Exit parameter 16
3
Exit parameter 17
4
Exit parameter 18
5
Exit parameter 19
6
Exit parameter 20
7
Exit parameter 21
AP D521 DFHAPEX AP 2 Exit part 3 Up to 200 bytes of each exit parameter:
1
Exit parameter 15
2
Exit parameter 16
3
Exit parameter 17
4
Exit parameter 18
5
Exit parameter 19
6
Exit parameter 20
7
Exit parameter 21
AP D522 DFHUEM Exc Recovery
1
EIB
2
Kernel error data
AP D523 DFHAPEX AP 2 Entry part 4 Up to 200 bytes of each exit parameter:
1
Exit parameter 22
2
Exit parameter 23
3
Exit parameter 24
4
Exit parameter 25
5
Exit parameter 26
6
Exit parameter 27
7
Exit parameter 28
AP D524 DFHAPEX AP 2 Exit part 4 Up to 200 bytes of each exit parameter:
1
Exit parameter 22
2
Exit parameter 23
3
Exit parameter 24
4
Exit parameter 25
5
Exit parameter 26
6
Exit parameter 27
7
Exit parameter 28
AP D525 DFHAPEX Exc User exit program failed, part 3 Up to 200 bytes of each exit parameter:
1
Exit parameter 15
2
Exit parameter 16
3
Exit parameter 17
4
Exit parameter 18
5
Exit parameter 19
6
Exit parameter 20
7
Exit parameter 21
AP D526 DFHAPEX Exc User exit program failed, part 4
1
Exit parameter 22
2
Exit parameter 23
3
Exit parameter 24
4
Exit parameter 25
5
Exit parameter 26
6
Exit parameter 27
7
Exit parameter 28
AP D527 DFHAPEX AP 1 GLUE entry
1
APEX parameter list
2
Register 12
3
Register 13
4
TCAPBAR
5
TCZLCDSA
AP D528 DFHAPEX AP 1 GLUE exit
1
APEX parameter list
2
Register 12
3
Register 13
4
TCAPBAR
5
TCZLCDSA
AP D529 DFHAPEX AP Exc GLUE error
1
APEX parameter list
AP D530 DFHUEIQ UE 1 Before inquire exit program
1
DFHUEIQ parameter list
AP D531 DFHUEIQ UE 1 After inquire exit program
1
DFHUEIQ parameter list
AP D532 DFHUEIQ Exc Recovery
1
DFHUEIQ parameter list
2
Kernel error data