The AUXTRSW parameter specifies whether you
want the auxiliary trace autoswitch facility.
- AUXTRSW={NO|ALL|NEXT}
- Valid values are as follows:
- NO
- Disables the autoswitch facility.
- NEXT
- Enables the autoswitch facility to switch to the next data set at end
of file of the first data set used for auxiliary trace. Coding NEXT permits
one switch only, and when the second data set is full, auxiliary trace is
switched off.
- ALL
- Enable the autoswitch facility to switch to the inactive data set at every
end of file. Coding ALL permits continuous switching between the two auxiliary
trace data sets, DFHAUXT and DFHBUXT, and whenever a data set is full, it
is closed and the other data set is opened.