DSNU764I csect-name FOLLOWING IS UP TO 119 BYTES OF RECORDFOR TABLE table-name, SEQNO seqno BEING PROCESSED AT THE TIME OF ERROR
Explanation
An abend occurred during the execution of the
CATMAINT utility, during the processing of the table, 'table-name',
with a sequence number of 'seqno'. The cause of the abend is one of
the following:
- The record sequence number was invalid.
- An unexpected return code was received from DSNUEXLO.
- The table name was not found in the load table (DSNUELTB).
- The parent record could not be positioned.
- The position OBID was zero (DSNUELTB has incorrect value).
- The record action code is incorrect.
Following this message, up to the first 119 bytes of the recordin question is displayed.
System action
Utility abends.
User response
Verify that the record in the unloaded data set is correct.
Severity
8 (error)