DSNU694I csect-name utility-name CANNOT CONTINUE BECAUSE NOT ENOUGH INFORMATION IS AVAILABLE
Explanation
The REPAIR utility does not have enough information to update the Db2 catalog for one of the following reasons:
- The utility is unable to find a V0 OBDREC in the system page.
- A system page does not exist.
- The utility is unable to find any information in the page set.
- csect-name
- The name of the control section that issued the message.
- utility-name
- The name of the utility. The name can be REPAIR CATALOG.
System action
The utility terminates. The catalog is not updated.
User response
Perform at least one INSERT or UPDATE operation on one of the partitions, or reorganize the table space. Then use the DSN1COPY utility to copy the physical file from the source and replace the target. If you receive message DSNU694I again, call IBM® Support.
Severity
8 (error)