DSNU404I csect-name LOCAL SITE AND RECOVERY SITE INCREMENTAL IMAGE COPIES ARE NOT SYNCHRONIZED FOR obj-type obj-qual.obj-name

Explanation

No incremental image copy can be made if
  1. The incremental image copy is requested only for a site other than the current site.
  2. The incremental image copies are requested for both sites but the most recent full image copy was made only for the current site.
  3. The incremental image copies are requested for both sites and the most recent full image copies were made for both sites, but between the most recent full image copy and current request, all incremental image copies were made for current site only.

System action

The utility will terminate with a return code of 8, and will not take the image copy or update the SYSCOPY table.

User response

Take another full image copy of the TABLESPACE for both LOCAL site and RECOVERY site or change the request to make incremental image copy only for current site.

Severity

8(error)