DSNU058I csect-name utility-name UTILITY NOT ALLOWED AGAINST AN OBJECT IN RECOVER PENDING STATE

Explanation

An attempt has been made to execute a utility against an object that is in RECOVER PENDING STATE. CHECK, COPY, MODIFY, LOAD, QUIESCE, REORG, and RUNSTAT are not allowed.

System action

Utility processing is not initiated.

System programmer response

Determine which of the three utilities, LOAD REPLACE, RECOVER, or REPAIR, should be used to remove the object from the RECOVER PENDING STATE.

User response

Remove the object from the RECOVERY PENDING STATE by using either LOAD REPLACE, RECOVER, or REPAIR against the object. Resubmit the job.

Severity