DSNTIPN: Tracing parameters panel

The entries on the DSNTIPN panel affect the audit, global, accounting, and monitor traces and the checkpoint frequency.

Because space on this panel is limited, some input fields are not wide enough to display the entire contents of the field at one time. These fields are defined as ISPF scrollable fields, which let you see the field contents. A less-than symbol (<) or a greater-than (>) symbol denotes a scrollable field. A > symbol indicates that the field can be scrolled to the right, and a < symbol indicates that the field can be scrolled to the left. You can position your cursor in the field and use ISPF scroll commands LEFT and RIGHT to scroll through the field. To see the entire contents of the field at one time, type EXPAND in the command field, position your cursor in the scrollable field, and press Enter. (Alternatively, you can assign your PF keys to be the LEFT, RIGHT, and EXPAND commands.)

Figure 1. Tracing panel: DSNTIPN
Start of change
 DSNTIPN         INSTALL DB2 - TRACING PARAMETERS

 ===> _
 Enter data below:

  1  AUDIT TRACE        ===> NO       > Audit classes to start. NO,YES,list
  2  TRACE AUTO START   ===> NO       > Global classes to start. YES,NO,list
  3  TRACE SIZE         ===> 64K        Trace table size in bytes. 4K-396K
  4  SMF ACCOUNTING     ===> 1        > Accounting classes to start. NO,YES,list
  5  SMF STATISTICS     ===> YES      > Statistics classes to start. NO,YES,list
  6  STATISTICS TIME    ===> 1          Time interval in minutes. 1-60
  7  STATISTICS SYNC    ===> NO         Synchronization within the hour. NO,0-59
  8  DATASET STATS TIME ===> 5          Time interval in minutes. 1-60
  9  MONITOR TRACE      ===> NO       > Monitor classes to start. NO,YES,list
 10  MONITOR SIZE       ===> 1M         Default monitor buffer size. 1M-64M
 11  UNICODE IFCIDS     ===> NO         Include UNICODE data when writing IFCIDS
 12  DDF/RRSAF ACCUM    ===> 10         Rollup accting for DDF/RRSAF. NO, 2-64K
 13  AGGREGATION FIELDS ===> 0          Rollup accting aggregation fields
 14  COMPRESS SMF RECS  ===> OFF        Compress trace records destined for SMF

 PRESS:   ENTER to continue   RETURN to exit   HELP for more information
 
End of change