00E50711   

Explanation

An error occurred in a latch manager function and the status of one or more execution units waiting for a latch is indoubt. The latch manager functional recovery routine could not determine whether all waiting execution units had been resumed.

System action

The DB2® subsystem terminates with this reason code.

Operator response

Notify the system programmer of the failure and restart DB2.

System programmer response

Scan the SYS1.LOGREC entries looking for one or more DB2 abends immediately prior to the subsystem termination. If you suspect an error in DB2, you might need to report the problem. For information about identifying and reporting the problem, see Collecting diagnostic data.

Problem determination

A DB2 dump of the original error was requested and a record entered into SYS1.LOGREC. Refer to the appropriate CICS® documentation for information about X'04F' and X'04E' abend completion codes.