00E50040   

Explanation

DB2® subsystem termination was invoked following an unrecoverable error while processing a terminate allied agent request at the thread, sign on, or identify level. The FRR (DSNVTFRR) covering module DSNVTRTH was unable to recover. This is a subsystem termination reason code.

System action

The DB2 subsystem is terminated.

Operator response

Notify the system programmer, and restart DB2.

System programmer response

If you suspect an error in DB2, you might need to report the problem. For information about identifying and reporting the problem, see Collecting diagnostic data.

Problem determination

Scan the MVS™ system log and the contents of SYS1.LOGREC for DB2 abends occurring immediately before the system termination message DSNV086E. Follow the failure analysis procedures for the specific abends. Refer to the appropriate CICS® documentation for information about X'04F' and X'04E' abend completion codes.

Collect the following diagnostic items:
  • Console output from the system on which the job was run, and a listing of the SYSLOG data set for the period of time that spans the failure.
  • Listing of SYS1.LOGREC data set, obtained by executing IFCEREP1.