00E5001A   

Explanation

A CANCEL THREAD command caused the thread to be terminated. A dump is provided for diagnostic purposes as a result of the CANCEL command DUMP keyword.

System action

DB2® writes a SYS1.LOGREC record and requests an SVC dump. The execution unit abends.

Operator response

Notify the system programmer.

System programmer response

The command might have been used to terminate a thread that was in a state where no processing was occurring and the thread could not continue.

If you suspect an internal DB2 error, obtain a copy of the SYS1.LOGREC listing and the SVC dump. Determine the failing environment (DB2, IMS™, CICS®, or TSO).

Problem determination

If you suspect an error in DB2, you might need to report the problem. For information about identifying and reporting the problem, see Collecting diagnostic data.

Collect the following diagnostic items:
  • Console output from the system on which the job was run, and a listing of the SYSLOG data set for the period of time that spans the failure.
  • Dynamic dump, taken to SYS1.DUMPxx data set, by DB2 (04E and 04F abends).
  • Listing of SYS1.LOGREC data set, obtained by executing IFCEREP1.

The module that was suspended while waiting for some action to be taken is the module that issued the abend.