Turn on RMF collection of coupling facility and lock data.
If OMEGAMON XE on z/OS has
been configured to use RMF coupling facility data (RMF
Collection = CF/XCF
), you must ensure that collection of
coupling facility details is turned on in every RMF Monitor
III in the Sysplex. If OMEGAMON XE on z/OS has
been configured to use RMF lock data (RMF Collection
= LOCK
), ensure that collection of LOCK data is turned on
in every RMF Monitor III in the Sysplex.
In RMF, collection of coupling facility details
is enabled by setting CFDETAIL in the Monitor III parameters in SYS1.PARMLIB(ERBRMFnn).
Collection can also be enabled dynamically by issuing the following
operator command:
ROUTE *ALL,MODIFY RMF,MODIFY III,CFDETAIL
See the section on Defining Parameters for RMF Monitor
III and the section on CFDETAIL in the RMF User's
Guide for details.You can enable collection of lock data by setting LOCK as the default
in SYS1.PARMLIB(ERBRMFnn) or use the dynamic command
/MODIFY RMF,MODIFY III,LOCK
to turn on collection.If OMEGAMON XE on z/OS has
been configured to use RMF data for both coupling facility
and lock data (RMF Collection = ALL
), both CFDETAIL
and LOCK must be set.