Turn on RMF collection of coupling facility and lock data.

If OMEGAMON XE on z/OS has been configured to use RMF coupling facility data (RMF Collection = CF/XCF), you must ensure that collection of coupling facility details is turned on in every RMF Monitor III in the Sysplex. If OMEGAMON XE on z/OS has been configured to use RMF lock data (RMF Collection = LOCK), ensure that collection of LOCK data is turned on in every RMF Monitor III in the Sysplex.

In RMF, collection of coupling facility details is enabled by setting CFDETAIL in the Monitor III parameters in SYS1.PARMLIB(ERBRMFnn). Collection can also be enabled dynamically by issuing the following operator command:
ROUTE *ALL,MODIFY RMF,MODIFY III,CFDETAIL
See the section on Defining Parameters for RMF Monitor III and the section on CFDETAIL in the RMF User's Guide for details.
You can enable collection of lock data by setting LOCK as the default in SYS1.PARMLIB(ERBRMFnn) or use the dynamic command
/MODIFY RMF,MODIFY III,LOCK
to turn on collection.

If OMEGAMON XE on z/OS has been configured to use RMF data for both coupling facility and lock data (RMF Collection = ALL), both CFDETAIL and LOCK must be set.