Removing and replacing the time-of-day battery in the 9006-12P system

Learn how to remove and replace the time-of-day battery in the IBM® Power® System LC921 (9006-12P) system.

Before you begin

Power off the system and place it in the service position. For instructions, see Preparing the 9006-12P system to remove and replace internal parts.

Procedure

  1. Attach the electrostatic discharge (ESD) wrist strap.
    The ESD wrist strap must be connected to an unpainted metal surface until the service procedure is completed, and if applicable, until the service access cover is replaced.
    Attention:
    • Attach an electrostatic discharge (ESD) wrist strap to the front ESD jack, to the rear ESD jack, or to an unpainted metal surface of your hardware to prevent the electrostatic discharge from damaging your hardware.
    • When you use an ESD wrist strap, follow all electrical safety procedures. An ESD wrist strap is used for static control. It does not increase or decrease your risk of receiving electric shock when using or working on electrical equipment.
    • If you do not have an ESD wrist strap, just prior to removing the product from ESD packaging and installing or replacing hardware, touch an unpainted metal surface of the system for a minimum of 5 seconds. If at any point in this service process you move away from the system, it is important to again discharge yourself by touching an unpainted metal surface for at least 5 seconds before you continue with the service process.
  2. If the time-of-day battery is covered by a PCIe adapter, move the PCIe adapter out of the way.
  3. Remove the time-of-day battery (A) by pushing the tab (B) away from the battery as shown in Figure 1.
    When you remove the battery, do not use a metallic tool to disengage it from its slot.
    Figure 1. Removing the time-of-day battery
    Removing the time-of-day battery
  4. Replace the time-of-day battery (A).
    The orientation of the + of the battery is up as shown in the following figure.
    Figure 2. Replacing the time-of-day battery
    Replacing the time-of-day battery
  5. If you moved a PCIe adapter to access the battery, replace the PCIe adapter.

What to do next

Prepare the system for operation. For instructions, see Preparing the 9006-12P system for operation after you remove and replace internal parts.

You need to set the system's time after replacing the battery. You can set the time after the system is running by logging into the web GUI.